station_GEOTRC | cruise_part | cast_GEOTRC | date | time2 | time | latitude | longitude | type | sample_bottle_GEOTRC | sample_GEOTRC | property | code | who | comments |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
integer | text | integer | unitless | HHMMSS | UTC | degrees_north | degrees_east | text | integer | integer | text | integer | text | text |
1 | A | 1 | 20111107 | 034512 | 2011-11-07T03:45:12.00Z | 39.70065 | -69.80291 | GT-C | 4 | 6115 | salt | 2 | cms | Bottle salt value agrees with CTD; water column and adjacent parameters; code acceptable. Analyst: SaltBtl_21 reading suspect; no obvious cause. |
1 | A | 1 | 20111107 | 034512 | 2011-11-07T03:45:12.00Z | 39.70065 | -69.80291 | GT-C | 5 | 6116 | bot | 2 | clog | Re-snapped top ball-valve shut; good seal; pressurized well. |
1 | A | 1 | 20111107 | 034512 | 2011-11-07T03:45:12.00Z | 39.70065 | -69.80291 | GT-C | 5 | 6116 | salt | 3 | cms | Bottle salt value low vs.CTDS1/CTDS2 for 1000-2000db; code questionable.. |
1 | A | 1 | 20111107 | 034512 | 2011-11-07T03:45:12.00Z | 39.70065 | -69.80291 | GT-C | 18 | 6129 | salt | 2 | cms | Bottle salt value agrees with CTD; water column and adjacent parameters; code acceptable. Analyst: SaltBtl_7 readings bad; thimble came out with cap. |
1 | A | 1 | 20111107 | 034512 | 2011-11-07T03:45:12.00Z | 39.70065 | -69.80291 | GT-C | 23 | 6134 | po4 | 4 | mtm | Values are high and not the same (which they should be due to duplicate trips); peaks are slightly funky but sampling error also likely |
1 | A | 1 | 20111107 | 034512 | 2011-11-07T03:45:12.00Z | 39.70065 | -69.80291 | GT-C | 24 | 6135 | po4 | 4 | mtm | Values are high and not the same (which they should be due to duplicate trips); peaks are slightly funky but sampling error also likely |
1 | A | 2 | 20111107 | 060505 | 2011-11-07T06:05:04.80Z | 39.70143 | -69.82674 | SIOR | 1 | 6136 | po4 | 3 | mtm | value is high compared to cast and similar depths on other casts; no analytical errors noted. |
1 | A | 2 | 20111107 | 060505 | 2011-11-07T06:05:04.80Z | 39.70143 | -69.82674 | SIOR | 4 | 6139 | bot | 2 | slog | Lanyard spigot slow and weeps after sampling started. |
1 | A | 2 | 20111107 | 060505 | 2011-11-07T06:05:04.80Z | 39.70143 | -69.82674 | SIOR | 6 | 6141 | bot | 9 | slog | Bottle did not trip. Lanyard caught on 2 latches. |
1 | A | 2 | 20111107 | 060505 | 2011-11-07T06:05:04.80Z | 39.70143 | -69.82674 | SIOR | 7 | 6142 | bot | 2 | slog | Bottom cap weeping after sampling started. Probably due to stiff/hard o-rings. |
1 | A | 4 | 20111107 | 180646 | 2011-11-07T18:06:46.20Z | 39.69238 | -69.79636 | SIOR | 7 | 6162 | salt | 3 | cms | Salt value low compared to CTDS1/CTDS2 at 2040db; code questionable. |
1 | A | 4 | 20111107 | 180646 | 2011-11-07T18:06:46.20Z | 39.69238 | -69.79636 | SIOR | 10 | 6165 | salt | 2 | cms | Bottle salt value agrees with CTD; water column and adjacent parameters; code acceptable. Analyst: SaltBtl_22; Rim chip - seal does NOT appear to be compromised. Old injury; not from this cruise. |
1 | A | 4 | 20111107 | 180646 | 2011-11-07T18:06:46.20Z | 39.69238 | -69.79636 | SIOR | 11 | 6166 | salt | 2 | cms | Bottle salt value agrees with CTD; water column and adjacent parameters; code acceptable. Analyst: SaltBtl_23; readings kept climbing; cause unknown. Salt value reasonable for water depth (1510m) and agrees with CTDS1/CTDS2. |
1 | A | 5 | 20111107 | 192752 | 2011-11-07T19:27:52.20Z | 39.68594 | -69.81301 | GT-C | 14 | 6178 | no2nm | 5 | web | out of working range |
1 | A | 5 | 20111107 | 192752 | 2011-11-07T19:27:52.20Z | 39.68594 | -69.81301 | GT-C | 14 | 6178 | po4nm | 5 | web | out of working range |
1 | A | 5 | 20111107 | 192752 | 2011-11-07T19:27:52.20Z | 39.68594 | -69.81301 | GT-C | 16 | 6176 | no2nm | 3 | web | out of calibration range; but within working range |
1 | A | 5 | 20111107 | 192752 | 2011-11-07T19:27:52.20Z | 39.68594 | -69.81301 | GT-C | 16 | 6176 | po4nm | 5 | web | out of working range |
1 | A | 5 | 20111107 | 192752 | 2011-11-07T19:27:52.20Z | 39.68594 | -69.81301 | GT-C | 18 | 6174 | no2nm | 3 | web | out of calibration range; but within working range |
1 | A | 5 | 20111107 | 192752 | 2011-11-07T19:27:52.20Z | 39.68594 | -69.81301 | GT-C | 18 | 6174 | po4nm | 5 | web | out of working range |
1 | A | 5 | 20111107 | 192752 | 2011-11-07T19:27:52.20Z | 39.68594 | -69.81301 | GT-C | 20 | 6172 | no2nm | 3 | web | out of calibration range; but within working range |
1 | A | 5 | 20111107 | 192752 | 2011-11-07T19:27:52.20Z | 39.68594 | -69.81301 | GT-C | 20 | 6172 | po4nm | 5 | web | out of working range |
1 | A | 5 | 20111107 | 192752 | 2011-11-07T19:27:52.20Z | 39.68594 | -69.81301 | GT-C | 21 | 6171 | salt | 3 | cms | Bottle salt value extremely low; however sample taken in high gradient region code questionable. |
1 | A | 5 | 20111107 | 192752 | 2011-11-07T19:27:52.20Z | 39.68594 | -69.81301 | GT-C | 22 | 6170 | no3nm | 3 | web | out of calibration range; but within working range |
1 | A | 5 | 20111107 | 192752 | 2011-11-07T19:27:52.20Z | 39.68594 | -69.81301 | GT-C | 22 | 6170 | po4nm | 5 | web | out of working range |
1 | A | 5 | 20111107 | 192752 | 2011-11-07T19:27:52.20Z | 39.68594 | -69.81301 | GT-C | 22 | 6170 | salt | 3 | cms | Bottle salt value extremely low; however sample taken in high gradient region code questionable. |
1 | A | 5 | 20111107 | 192752 | 2011-11-07T19:27:52.20Z | 39.68594 | -69.81301 | GT-C | 24 | 6168 | no3nm | 3 | web | out of calibration range; but within working range |
1 | A | 5 | 20111107 | 192752 | 2011-11-07T19:27:52.20Z | 39.68594 | -69.81301 | GT-C | 24 | 6168 | po4nm | 5 | web | out of working range |
1 | A | 6 | 20111107 | 224110 | 2011-11-07T22:41:10.20Z | 39.66579 | -69.815 | SIOR | 1 | 6206 | o2 | 5 | cms | Sample lost. Analytical program froze; manual system reboot. |
1 | A | 7 | 20111108 | 035253 | 2011-11-08T03:52:52.80Z | 39.69479 | -69.80779 | SIOR | 7 | 6199 | salt | 2 | cms | Bottle salt value agrees with CTD; water column and adjacent parameters; code acceptable. Analyst: SaltBtl_7 got distracted and pulled sample bottle before second reading. No reason to suspect reading otherwise. |
1 | A | 7 | 20111108 | 035253 | 2011-11-08T03:52:52.80Z | 39.69479 | -69.80779 | SIOR | 11 | 6203 | reft | 3 | mcj | SBE35RT +0.013 vs CTDT: taken at top of thermocline; in a gradient. Code questionable. |
1 | A | 7 | 20111108 | 035253 | 2011-11-08T03:52:52.80Z | 39.69479 | -69.80779 | SIOR | 12 | 6204 | salt | 3 | mcj | Salt value -0.025 vs CTDS; at small gradient in mixed layer. code questionable. |
1 | A | 9 | 20111108 | 111359 | 2011-11-08T11:13:58.80Z | 39.69269 | -69.8644 | SIOR | 6 | 6231 | bot | 9 | slog | Bottle did not trip: Loading error; lanyard caught on 2 latches. |
1 | A | 9 | 20111108 | 111359 | 2011-11-08T11:13:58.80Z | 39.69269 | -69.8644 | SIOR | 7 | 6232 | reft | 3 | mcj | SBE35RT -0.011 vs CTDT; reading unstable: taken in a small gradient. Code questionable. |
1 | A | 9 | 20111108 | 111359 | 2011-11-08T11:13:58.80Z | 39.69269 | -69.8644 | SIOR | 11 | 6236 | reft | 3 | mcj | SBE35RT +0.015 vs CTDT; reading unstable; taken in a gradient. Code questionable. |
1 | A | 10 | 20111108 | 152357 | 2011-11-08T15:23:57.00Z | 39.69943 | -69.79897 | SIOR | 5 | 6242 | reft | 3 | mcj | unstable SBE35T reading; taken in a small gradient. Code questionable. |
1 | A | 10 | 20111108 | 152357 | 2011-11-08T15:23:57.00Z | 39.69943 | -69.79897 | SIOR | 6 | 6243 | reft | 3 | mcj | unstable SBE35T reading; taken in a small gradient. Code questionable. |
1 | A | 10 | 20111108 | 152357 | 2011-11-08T15:23:57.00Z | 39.69943 | -69.79897 | SIOR | 11 | 6248 | salt | 3 | mcj | Salt value +0.035 vs CTDS; middle of high gradient. Code questionable. |
2 | A | 1 | 20111108 | 203439 | 2011-11-08T20:34:39.00Z | 39.34944 | -69.54207 | GT-C | 2 | 6273 | bot | 3 | clog | leak from GoFlo spine; GF-34 replaced with GF-33 after this cast. |
2 | A | 1 | 20111108 | 203439 | 2011-11-08T20:34:39.00Z | 39.34944 | -69.54207 | GT-C | 5 | 6270 | salt | 3 | cms | Salt value low compared to CTDS1/CTDS2; low for 1000-2000db range; code questionable |
2 | A | 1 | 20111108 | 203439 | 2011-11-08T20:34:39.00Z | 39.34944 | -69.54207 | GT-C | 12 | 6263 | salt | 2 | rlp | Bottle salt compares well with CTD; water column and adjacent parameters; code acceptable. Analyst: SaltBtl_13: Bad rim chip. Seal NOT compromised. Old injury. |
2 | A | 2 | 20111108 | 231600 | 2011-11-08T23:16:00.00Z | 39.34933 | -69.54976 | SIOR | 11 | 6285 | salt | 2 | rlp | Bottle salt compares well with CTD; water column and adjacent parameters; code acceptable. Analyst: SaltBtl_11: Rim chip; Seal is NOT compromised; did not notice it before but could be old injury as it is small. |
2 | A | 4 | 20111109 | 113006 | 2011-11-09T11:30:06.00Z | 39.35003 | -69.54001 | GT-C | 14 | 6305 | no2nm | 5 | web | out of working range |
2 | A | 4 | 20111109 | 113006 | 2011-11-09T11:30:06.00Z | 39.35003 | -69.54001 | GT-C | 14 | 6305 | po4nm | 5 | web | out of working range |
2 | A | 4 | 20111109 | 113006 | 2011-11-09T11:30:06.00Z | 39.35003 | -69.54001 | GT-C | 16 | 6303 | no2nm | 5 | web | out of working range |
2 | A | 4 | 20111109 | 113006 | 2011-11-09T11:30:06.00Z | 39.35003 | -69.54001 | GT-C | 16 | 6303 | po4nm | 5 | web | out of working range |
2 | A | 4 | 20111109 | 113006 | 2011-11-09T11:30:06.00Z | 39.35003 | -69.54001 | GT-C | 18 | 6301 | no2nm | 5 | web | out of working range |
2 | A | 4 | 20111109 | 113006 | 2011-11-09T11:30:06.00Z | 39.35003 | -69.54001 | GT-C | 18 | 6301 | po4nm | 5 | web | out of working range |
2 | A | 4 | 20111109 | 113006 | 2011-11-09T11:30:06.00Z | 39.35003 | -69.54001 | GT-C | 20 | 6299 | no2nm | 5 | web | out of working range |
2 | A | 4 | 20111109 | 113006 | 2011-11-09T11:30:06.00Z | 39.35003 | -69.54001 | GT-C | 20 | 6299 | po4nm | 5 | web | out of working range |
2 | A | 4 | 20111109 | 113006 | 2011-11-09T11:30:06.00Z | 39.35003 | -69.54001 | GT-C | 21 | 6298 | salt | 3 | cms | Salt value differs with CTDS1/CTDS2 by more than +- 0.030. High gradient region in top 50m. |
2 | A | 4 | 20111109 | 113006 | 2011-11-09T11:30:06.00Z | 39.35003 | -69.54001 | GT-C | 22 | 6297 | no2nm | 3 | web | out of calibration range; but within working range |
2 | A | 4 | 20111109 | 113006 | 2011-11-09T11:30:06.00Z | 39.35003 | -69.54001 | GT-C | 22 | 6297 | no3nm | 3 | web | out of calibration range; but within working range |
2 | A | 4 | 20111109 | 113006 | 2011-11-09T11:30:06.00Z | 39.35003 | -69.54001 | GT-C | 22 | 6297 | po4nm | 5 | web | out of working range |
2 | A | 4 | 20111109 | 113006 | 2011-11-09T11:30:06.00Z | 39.35003 | -69.54001 | GT-C | 22 | 6297 | salt | 3 | cms | Salt value differs with CTDS1/CTDS2 by more than +- 0.030. High gradient region in top 50m. |
2 | A | 4 | 20111109 | 113006 | 2011-11-09T11:30:06.00Z | 39.35003 | -69.54001 | GT-C | 23 | 6296 | salt | 3 | cms | Salt value differs with CTDS1/CTDS2 by more than +- 0.030. High gradient region in top 50m. |
2 | A | 4 | 20111109 | 113006 | 2011-11-09T11:30:06.00Z | 39.35003 | -69.54001 | GT-C | 24 | 6295 | bot | 2 | slog | flow rate too slow through membrane; Hg_Total sample taken through Acropak. |
2 | A | 4 | 20111109 | 113006 | 2011-11-09T11:30:06.00Z | 39.35003 | -69.54001 | GT-C | 24 | 6295 | no3nm | 3 | web | out of calibration range; but within working range |
2 | A | 4 | 20111109 | 113006 | 2011-11-09T11:30:06.00Z | 39.35003 | -69.54001 | GT-C | 24 | 6295 | po4nm | 5 | web | out of working range |
2 | A | 4 | 20111109 | 113006 | 2011-11-09T11:30:06.00Z | 39.35003 | -69.54001 | GT-C | 24 | 6295 | salt | 3 | cms | Salt value differs with CTDS1/CTDS2 by more than +- 0.030. High gradient region in top 50m. |
2 | A | 5 | 20111109 | 123102 | 2011-11-09T12:31:01.80Z | 39.35003 | -69.54002 | SIOR | 6 | 6324 | reft | 3 | mcj | SBE35T -0.015/-0.020 vs CTDT1/CTDT2; unstable SBE35T reading. Code questionable. |
2 | A | 5 | 20111109 | 123102 | 2011-11-09T12:31:01.80Z | 39.35003 | -69.54002 | SIOR | 7 | 6325 | o2 | 2 | cms | Sample run out of order. Flasks match sample log sheet; however values more closely match water column when switched with 508 flask 882. |
2 | A | 5 | 20111109 | 123102 | 2011-11-09T12:31:01.80Z | 39.35003 | -69.54002 | SIOR | 8 | 6326 | o2 | 2 | cms | Sample run out of order. Flasks match sample log sheet; however values more closely match water column when switched with 507 flask 886. |
2 | A | 5 | 20111109 | 123102 | 2011-11-09T12:31:01.80Z | 39.35003 | -69.54002 | SIOR | 9 | 6327 | o2 | 5 | cms | Sample accidentally destroyed. |
2 | A | 5 | 20111109 | 123102 | 2011-11-09T12:31:01.80Z | 39.35003 | -69.54002 | SIOR | 11 | 6329 | salt | 2 | rlp | Bottle salt compares well with CTD; water column and adjacent parameters; code acceptable. Analyst: SaltBtl_23: thimble came out with cap; probable contamination from liquid under cap. |
2 | A | 6 | 20111109 | 161609 | 2011-11-09T16:16:09.00Z | 39.35001 | -69.54005 | SIOR | 5 | 6335 | salt | 2 | rlp | Bottle salt compares well with CTD; water column and adjacent parameters; code acceptable. Analyst: SaltBtl_29: first reading anomalous; suspect air bubble in coil arm. |
2 | A | 6 | 20111109 | 161609 | 2011-11-09T16:16:09.00Z | 39.35001 | -69.54005 | SIOR | 8 | 6338 | reft | 3 | mcj | Somewhat unstable SBE35T reading in gradient. Code questionable. |
2 | A | 6 | 20111109 | 161609 | 2011-11-09T16:16:09.00Z | 39.35001 | -69.54005 | SIOR | 8 | 6338 | salt | 3 | mcj | Salt value -0.025 vs CTDS; high gradient region. Code questionable. |
2 | A | 6 | 20111109 | 161609 | 2011-11-09T16:16:09.00Z | 39.35001 | -69.54005 | SIOR | 10 | 6340 | reft | 3 | mcj | Unstable SBE35T reading in gradient. Code questionable. |
2 | A | 6 | 20111109 | 161609 | 2011-11-09T16:16:09.00Z | 39.35001 | -69.54005 | SIOR | 10 | 6340 | salt | 3 | mcj | Salt value +0.04 vs CTDS; bottom of mixed layer. Code questionable. |
3 | A | 1 | 20111110 | 123623 | 2011-11-10T12:36:22.80Z | 38.68832 | -69.08994 | GT-C | 3 | 6375 | bot | 2 | clog | GoFlo not tripped in slow mode. |
3 | A | 1 | 20111110 | 123623 | 2011-11-10T12:36:22.80Z | 38.68832 | -69.08994 | GT-C | 4 | 6374 | bot | 2 | clog | GoFlo not tripped in slow mode. |
3 | A | 1 | 20111110 | 123623 | 2011-11-10T12:36:22.80Z | 38.68832 | -69.08994 | GT-C | 14 | 6364 | no2nm | 3 | web | out of calibration range; but within working range |
3 | A | 1 | 20111110 | 123623 | 2011-11-10T12:36:22.80Z | 38.68832 | -69.08994 | GT-C | 14 | 6364 | po4nm | 5 | web | out of working range |
3 | A | 1 | 20111110 | 123623 | 2011-11-10T12:36:22.80Z | 38.68832 | -69.08994 | GT-C | 16 | 6362 | no2nm | 3 | web | out of calibration range; but within working range |
3 | A | 1 | 20111110 | 123623 | 2011-11-10T12:36:22.80Z | 38.68832 | -69.08994 | GT-C | 16 | 6362 | po4nm | 5 | web | out of working range |
3 | A | 1 | 20111110 | 123623 | 2011-11-10T12:36:22.80Z | 38.68832 | -69.08994 | GT-C | 18 | 6360 | no2nm | 3 | web | out of calibration range; but within working range |
3 | A | 1 | 20111110 | 123623 | 2011-11-10T12:36:22.80Z | 38.68832 | -69.08994 | GT-C | 18 | 6360 | po4nm | 5 | web | out of working range |
3 | A | 1 | 20111110 | 123623 | 2011-11-10T12:36:22.80Z | 38.68832 | -69.08994 | GT-C | 19 | 6359 | salt | 3 | cms | Bottle salt -0.04 vs. CTD; but matches 120 in high gradient region; code questionable. |
3 | A | 1 | 20111110 | 123623 | 2011-11-10T12:36:22.80Z | 38.68832 | -69.08994 | GT-C | 20 | 6358 | po4nm | 5 | web | out of working range |
3 | A | 1 | 20111110 | 123623 | 2011-11-10T12:36:22.80Z | 38.68832 | -69.08994 | GT-C | 20 | 6358 | salt | 3 | cms | Bottle salt -0.04 vs. CTD; but matches 119 in high gradient region; code questionable. |
3 | A | 2 | 20111110 | 150027 | 2011-11-10T15:00:27.00Z | 38.67405 | -69.11024 | SIOR | 6 | 6383 | salt | 2 | rlp | Analyst: SaltBtl_6: thimble came out with cap. Readings erratic. |
3 | A | 2 | 20111110 | 150027 | 2011-11-10T15:00:27.00Z | 38.67405 | -69.11024 | SIOR | 7 | 6384 | bot | 2 | slog | Guide pin came out of spigot stem; replaced after sampling. |
3 | A | 2 | 20111110 | 150027 | 2011-11-10T15:00:27.00Z | 38.67405 | -69.11024 | SIOR | 9 | 6386 | reft | 3 | mcj | very unstable SBE35T reading in gradient. Code questionable. |
3 | A | 4 | 20111111 | 032602 | 2011-11-11T03:26:01.80Z | 38.71668 | -69.03079 | GT-C | 7 | 6415 | bot | 2 | clog | Much extra wire out; very slow mode at GoFlo trip. |
3 | A | 4 | 20111111 | 032602 | 2011-11-11T03:26:01.80Z | 38.71668 | -69.03079 | GT-C | 8 | 6414 | bot | 4 | clog | GoFlo did not trip properly; top ball-valve open. Only nutrients and Salinity were sampled; code bad. |
3 | A | 4 | 20111111 | 032602 | 2011-11-11T03:26:01.80Z | 38.71668 | -69.03079 | GT-C | 8 | 6414 | no2 | 4 | mcj | Did not trip properly; top ball-valve open. Nutrients were sampled anyways; code bad. |
3 | A | 4 | 20111111 | 032602 | 2011-11-11T03:26:01.80Z | 38.71668 | -69.03079 | GT-C | 8 | 6414 | no3 | 4 | mcj | Did not trip properly; top ball-valve open. Nutrients were sampled anyways; code bad. |
3 | A | 4 | 20111111 | 032602 | 2011-11-11T03:26:01.80Z | 38.71668 | -69.03079 | GT-C | 8 | 6414 | po4 | 4 | mcj | Did not trip properly; top ball-valve open. Nutrients were sampled anyways; code bad. |
3 | A | 4 | 20111111 | 032602 | 2011-11-11T03:26:01.80Z | 38.71668 | -69.03079 | GT-C | 8 | 6414 | salt | 4 | mcj | Analyst: SaltBtl_17: thimble came out with cap; readings erratic. Hit abort instead of keyboard entry. Data lost. Reading was 1.99715 (hand-entered). Did not trip properly; top ball-valve open. Salinity was sampled anyways; code bad. |
3 | A | 4 | 20111111 | 032602 | 2011-11-11T03:26:01.80Z | 38.71668 | -69.03079 | GT-C | 8 | 6414 | sio3 | 4 | mcj | Did not trip properly; top ball-valve open. Nutrients were sampled anyways; code bad. |
3 | A | 4 | 20111111 | 032602 | 2011-11-11T03:26:01.80Z | 38.71668 | -69.03079 | GT-C | 18 | 6404 | no3 | 4 | mtm | Analyst: no3; po4 values are high and do not match those of bottle 17; no analytical errors noted |
3 | A | 4 | 20111111 | 032602 | 2011-11-11T03:26:01.80Z | 38.71668 | -69.03079 | GT-C | 18 | 6404 | po4 | 4 | mtm | Analyst: no3; po4 values are high and do not match those of bottle 17; no analytical errors noted |
3 | A | 4 | 20111111 | 091303 | 2011-11-11T09:13:03.00Z | 38.66881 | -69.11208 | GT-C | 18 | 6404 | salt | 4 | cms | Bottle value low vs CTD. Value matches 423 exactly. Other parameters also not aligned. Probable mis-trip; code bad. |
3 | A | 5 | 20111111 | 091303 | 2011-11-11T09:13:03.00Z | 38.66881 | -69.11208 | SIOR | 1 | 6425 | salt | 3 | cms | Bottle salt value is +0.020 vs. CTD; high for low gradient region; code questionable. |
3 | A | 5 | 20111111 | 091303 | 2011-11-11T09:13:03.00Z | 38.66881 | -69.11208 | SIOR | 8 | 6432 | po4 | 2 | mtm | Analyst: po4 value is slightly high; no analytical errors noted. |
3 | A | 6 | 20111111 | 141124 | 2011-11-11T14:11:24.00Z | 38.68242 | -69.08173 | SIOR | 7 | 6445 | o2 | 2 | cms | Bottle o2 value +0.0.242ml/l vs. CTD. High gradient region; water column changing rapidly in Gulf stream. Value matches up-trace. Code acceptable. |
3 | A | 6 | 20111111 | 141124 | 2011-11-11T14:11:24.00Z | 38.68242 | -69.08173 | SIOR | 9 | 6447 | o2 | 2 | cms | Bottle o2 value +0.453ml/l vs. CTD. High gradient region; water column changing rapidly in Gulf stream. Value matches up-trace. Code acceptable. |
3 | A | 6 | 20111111 | 141124 | 2011-11-11T14:11:24.00Z | 38.68242 | -69.08173 | SIOR | 9 | 6447 | salt | 3 | cms | Bottle salt value is +0.040 vs. CTD; in high gradient region. Code questionable. |
4 | A | 1 | 20111112 | 153833 | 2011-11-12T15:38:33.00Z | 38.32454 | -68.87254 | SIOR | 1 | 6469 | reft | 3 | mcj | SBE35T +0.014 vs CTDT; unstable SBE35T reading in a small gradient. Code questionable. |
4 | A | 1 | 20111112 | 153833 | 2011-11-12T15:38:33.00Z | 38.32454 | -68.87254 | SIOR | 3 | 6471 | reft | 3 | mcj | SBE35T -0.015 vs CTDT; unstable SBE35T reading in a gradient. Code questionable. |
4 | A | 1 | 20111112 | 153833 | 2011-11-12T15:38:33.00Z | 38.32454 | -68.87254 | SIOR | 4 | 6472 | bot | 9 | slog | Bottle 4 did not trip; cocked on wrong latch. |
4 | A | 1 | 20111112 | 153833 | 2011-11-12T15:38:33.00Z | 38.32454 | -68.87254 | SIOR | 7 | 6475 | reft | 3 | mcj | SBE35T -0.025/-0.035 vs CTDT1/CTDT2; unstable SBE35T reading. Code questionable. |
4 | A | 1 | 20111112 | 153833 | 2011-11-12T15:38:33.00Z | 38.32454 | -68.87254 | SIOR | 7 | 6475 | salt | 2 | cms | Bottle salt value agrees with CTD; water column and adjacent parameters. Analyst: SaltBtl_6; thimble came out with cap. Possible contamination. |
4 | A | 1 | 20111112 | 153833 | 2011-11-12T15:38:33.00Z | 38.32454 | -68.87254 | SIOR | 12 | 6480 | salt | 2 | cms | Bottle salt value agrees with CTD; water column and adjacent parameters. Analyst: SaltBtl_11; readings erratic. |
4 | A | 3 | 20111113 | 010940 | 2011-11-13T01:09:40.20Z | 38.32942 | -68.86069 | SIOR | 2 | 6490 | salt | 4 | cms | Bottle salt value high vs CTDS1/CTDS2 for low gradient region of water column; code questionable. Analyst: SaltBtl_14; thimble came out with cap; initial large jump; suspect contamination. |
4 | A | 4 | 20111113 | 060802 | 2011-11-13T06:08:01.80Z | 38.31914 | -68.86808 | SIOR | 8 | 6508 | o2 | 2 | slog | Possible bubble in o2 flask. ANALYST: O2 values nominal. |
5 | A | 1 | 20111113 | 193112 | 2011-11-13T19:31:12.00Z | 38.08208 | -68.70606 | GT-C | 7 | 6539 | salt | 3 | cms | Bottle salt value is high vs CTDS1/CTDS2 for ~600db; Code questionable. |
5 | A | 1 | 20111113 | 193112 | 2011-11-13T19:31:12.00Z | 38.08208 | -68.70606 | GT-C | 8 | 6538 | salt | 3 | cms | Bottle salt value is high vs CTDS1/CTDS2 for ~600db; Code questionable. |
5 | A | 1 | 20111113 | 193112 | 2011-11-13T19:31:12.00Z | 38.08208 | -68.70606 | GT-C | 13 | 6533 | no2nm | 3 | web | out of calibration range; but within working range |
5 | A | 1 | 20111113 | 193112 | 2011-11-13T19:31:12.00Z | 38.08208 | -68.70606 | GT-C | 13 | 6533 | po4nm | 5 | web | out of working range |
5 | A | 1 | 20111113 | 193112 | 2011-11-13T19:31:12.00Z | 38.08208 | -68.70606 | GT-C | 15 | 6531 | no2nm | 3 | web | out of calibration range; but within working range |
5 | A | 1 | 20111113 | 193112 | 2011-11-13T19:31:12.00Z | 38.08208 | -68.70606 | GT-C | 15 | 6531 | po4nm | 5 | web | out of working range |
5 | A | 1 | 20111113 | 193112 | 2011-11-13T19:31:12.00Z | 38.08208 | -68.70606 | GT-C | 17 | 6529 | po4nm | 5 | web | out of working range |
5 | A | 1 | 20111113 | 193112 | 2011-11-13T19:31:12.00Z | 38.08208 | -68.70606 | GT-C | 19 | 6527 | no3nm | 3 | web | out of calibration range; but within working range |
5 | A | 1 | 20111113 | 193112 | 2011-11-13T19:31:12.00Z | 38.08208 | -68.70606 | GT-C | 19 | 6527 | po4nm | 5 | web | out of working range |
5 | A | 2 | 20111113 | 210319 | 2011-11-13T21:03:19.20Z | 38.0789 | -68.71797 | SIOR | 2 | 6547 | reft | 3 | mcj | SBE35T -0.006 vs CTDT; somewhat high for deeper reading. Code questionable. |
5 | A | 2 | 20111113 | 210319 | 2011-11-13T21:03:19.20Z | 38.0789 | -68.71797 | SIOR | 9 | 6554 | o2 | 2 | cms | Bottle o2 value -0.267ml/l less than CTD. Tripped in high gradient region; value matches water column trend. Code acceptable. |
5 | A | 2 | 20111113 | 210319 | 2011-11-13T21:03:19.20Z | 38.0789 | -68.71797 | SIOR | 10 | 6555 | reft | 3 | mcj | SBE35T -0.030/-0.025 vs CTDT1/CTDT2; unstable SBE35T reading. Code questionable. |
5 | A | 2 | 20111113 | 210319 | 2011-11-13T21:03:19.20Z | 38.0789 | -68.71797 | SIOR | 13 | 6558 | salt | 2 | cms | Surface Pump sample. |
6 | A | 1 | 20111114 | 042846 | 2011-11-14T04:28:46.20Z | 37.56834 | -68.45008 | GT-C | 8 | 6576 | bot | 4 | mcj | Nutrients and salinity indicate GoFlo 25 apparently closed at a shallower depth than tripped. GoFlo 25 changed out after station 14. |
6 | A | 1 | 20111114 | 042846 | 2011-11-14T04:28:46.20Z | 37.56834 | -68.45008 | GT-C | 8 | 6576 | no2 | 4 | mcj | GoFlo did not close where expected; code nutrients bad. |
6 | A | 1 | 20111114 | 042846 | 2011-11-14T04:28:46.20Z | 37.56834 | -68.45008 | GT-C | 8 | 6576 | no3 | 4 | mcj | GoFlo did not close where expected; code nutrients bad. |
6 | A | 1 | 20111114 | 042846 | 2011-11-14T04:28:46.20Z | 37.56834 | -68.45008 | GT-C | 8 | 6576 | po4 | 4 | mcj | GoFlo did not close where expected; code nutrients bad. |
6 | A | 1 | 20111114 | 042846 | 2011-11-14T04:28:46.20Z | 37.56834 | -68.45008 | GT-C | 8 | 6576 | salt | 4 | mcj | Deep salinity is +0.005 vs CTDS and sample from 107 (tripped at same depth); GoFlo did not close where expected; code salinity bad. |
6 | A | 1 | 20111114 | 042846 | 2011-11-14T04:28:46.20Z | 37.56834 | -68.45008 | GT-C | 8 | 6576 | sio3 | 4 | mtm | value low and does not match sample 107 (tripped at same depth); GoFlo did not close where expected; code nutrients bad. |
6 | A | 1 | 20111114 | 042846 | 2011-11-14T04:28:46.20Z | 37.56834 | -68.45008 | GT-C | 14 | 6570 | salt | 2 | cms | Bottle value agrees with CTD values and water column trend; code acceptable. Analyst: SaltBtl_11; thimble came out part way; very full of water. Probable contamination. |
6 | A | 3 | 20111114 | 120949 | 2011-11-14T12:09:49.20Z | 37.5585 | -68.45766 | SIOR | 5 | 6588 | salt | 2 | cms | Bottle value agrees with CTD values and water column trend; code acceptable. Analyst: SaltBtl_5; thimble came out with cap - reading erratic. |
6 | A | 3 | 20111114 | 120949 | 2011-11-14T12:09:49.20Z | 37.5585 | -68.45766 | SIOR | 6 | 6589 | salt | 3 | mcj | Deep salinity +0.005 vs CTD; code questionable. |
6 | A | 6 | 20111115 | 065429 | 2011-11-15T06:54:28.80Z | 37.58743 | -68.40346 | SIOR | 2 | 6653 | salt | 2 | cms | Bottle value agrees with CTD values and water column trend; code acceptable. Analyst: SaltBtl_14; thimble came out with cap - probable contamination. |
6 | A | 6 | 20111115 | 065429 | 2011-11-15T06:54:28.80Z | 37.58743 | -68.40346 | SIOR | 6 | 6657 | reft | 3 | mcj | SBE35T +0.012 vs CTDT; unstable SBE35T reading; in a gradient. Code questionable. |
6 | A | 6 | 20111115 | 065429 | 2011-11-15T06:54:28.80Z | 37.58743 | -68.40346 | SIOR | 7 | 6658 | salt | 3 | mcj | bottle salt +0.06 vs CTDS; in gradient. Code questionable. |
6 | A | 6 | 20111115 | 065429 | 2011-11-15T06:54:28.80Z | 37.58743 | -68.40346 | SIOR | 8 | 6659 | salt | 3 | mcj | bottle salt -0.055 vs CTDS; in gradient. Code questionable. |
6 | A | 7 | 20111115 | 091452 | 2011-11-15T09:14:52.20Z | 37.60172 | -68.394 | GT-C | 13 | 6639 | salt | 3 | cms | Bottle value low for CTD in high gradient region. Adjacent parameters good. C1 and C2 differ greatly. Unstable; code questionable. |
6 | A | 7 | 20111115 | 091452 | 2011-11-15T09:14:52.20Z | 37.60172 | -68.394 | GT-C | 14 | 6638 | no2nm | 3 | web | out of calibration range; but within working range |
6 | A | 7 | 20111115 | 091452 | 2011-11-15T09:14:52.20Z | 37.60172 | -68.394 | GT-C | 14 | 6638 | po4nm | 5 | web | out of working range |
6 | A | 7 | 20111115 | 091452 | 2011-11-15T09:14:52.20Z | 37.60172 | -68.394 | GT-C | 14 | 6638 | salt | 3 | cms | Bottle value low for CTD in high gradient region. Adjacent parameters good. C1 and C2 differ greatly. Unstable; code questionable. |
6 | A | 7 | 20111115 | 091452 | 2011-11-15T09:14:52.20Z | 37.60172 | -68.394 | GT-C | 16 | 6636 | no2nm | 3 | web | out of calibration range; but within working range |
6 | A | 7 | 20111115 | 091452 | 2011-11-15T09:14:52.20Z | 37.60172 | -68.394 | GT-C | 16 | 6636 | po4nm | 5 | web | out of working range |
6 | A | 7 | 20111115 | 091452 | 2011-11-15T09:14:52.20Z | 37.60172 | -68.394 | GT-C | 17 | 6635 | salt | 3 | cms | Bottle value high for CTD in high gradient region. Adjacent parameters good. C1 and C2 differ greatly. Unstable; code questionable. |
6 | A | 7 | 20111115 | 091452 | 2011-11-15T09:14:52.20Z | 37.60172 | -68.394 | GT-C | 18 | 6634 | no3nm | 3 | web | out of calibration range; but within working range |
6 | A | 7 | 20111115 | 091452 | 2011-11-15T09:14:52.20Z | 37.60172 | -68.394 | GT-C | 18 | 6634 | po4nm | 5 | web | out of working range |
6 | A | 7 | 20111115 | 091452 | 2011-11-15T09:14:52.20Z | 37.60172 | -68.394 | GT-C | 18 | 6634 | salt | 3 | cms | Bottle value high for CTD in high gradient region. Adjacent parameters good. C1 and C2 differ greatly. Unstable; code questionable. |
6 | A | 8 | 20111115 | 111145 | 2011-11-15T11:11:45.00Z | 37.54367 | -68.43148 | SIOR | 7 | 6670 | reft | 3 | cms | SBE35T +0.017 vs CTDT; Unstable in high gradient region; code questionable. |
8 | A | 1 | 20111116 | 125612 | 2011-11-16T12:56:12.00Z | 35.41779 | -66.5265 | GT-C | 14 | 6697 | no2nm | 3 | web | out of calibration range; but within working range |
8 | A | 1 | 20111116 | 125612 | 2011-11-16T12:56:12.00Z | 35.41779 | -66.5265 | GT-C | 14 | 6697 | po4nm | 5 | web | out of working range |
8 | A | 1 | 20111116 | 125612 | 2011-11-16T12:56:12.00Z | 35.41779 | -66.5265 | GT-C | 16 | 6695 | no2nm | 3 | web | out of calibration range; but within working range |
8 | A | 1 | 20111116 | 125612 | 2011-11-16T12:56:12.00Z | 35.41779 | -66.5265 | GT-C | 16 | 6695 | po4nm | 5 | web | out of working range |
8 | A | 1 | 20111116 | 125612 | 2011-11-16T12:56:12.00Z | 35.41779 | -66.5265 | GT-C | 18 | 6693 | no2nm | 3 | web | out of calibration range; but within working range |
8 | A | 1 | 20111116 | 125612 | 2011-11-16T12:56:12.00Z | 35.41779 | -66.5265 | GT-C | 18 | 6693 | po4nm | 5 | web | out of working range |
8 | A | 1 | 20111116 | 125612 | 2011-11-16T12:56:12.00Z | 35.41779 | -66.5265 | GT-C | 20 | 6691 | no2nm | 3 | web | out of calibration range; but within working range |
8 | A | 1 | 20111116 | 125612 | 2011-11-16T12:56:12.00Z | 35.41779 | -66.5265 | GT-C | 20 | 6691 | po4nm | 5 | web | out of working range |
8 | A | 2 | 20111116 | 144216 | 2011-11-16T14:42:16.20Z | 35.41587 | -66.54681 | SIOR | 6 | 6716 | salt | 2 | cms | Bottle salt value agrees with CTD and water column profile; code acceptable. Analyst: SaltBtl_6: thimble came out with cap - probable contamination. |
8 | A | 4 | 20111116 | 223359 | 2011-11-16T22:33:58.80Z | 35.4258 | -66.65649 | SIOR | 4 | 6758 | salt | 2 | cms | Bottle salt value agrees with CTD and water column profile; code acceptable. Analyst: SaltBtl_16: thimble came out with cap; possible contamination. |
8 | A | 4 | 20111116 | 223359 | 2011-11-16T22:33:58.80Z | 35.4258 | -66.65649 | SIOR | 8 | 6762 | o2 | 2 | cms | Bottle o2 value 0.371 ml/l less vs CTD. Value matches trend in water column and up-trace; in high gradient region. Code acceptable. |
8 | A | 6 | 20111117 | 063600 | 2011-11-17T06:36:00.00Z | 35.41771 | -66.51712 | SIOR | 1 | 6768 | bot | 4 | mcj | salt; o2; CFC and nutrient values indicate this bottle probably tripped at the same depth as shallowest bottle (1500m). Possibly a lanyard hangup until last trip (niskins 1 and 12 are next to each other on rosette). Code as tripped at different depth than expected. |
8 | A | 6 | 20111117 | 063600 | 2011-11-17T06:36:00.00Z | 35.41771 | -66.51712 | SIOR | 1 | 6768 | no2 | 4 | mcj | deepest and shallowest (1500m) nutrient values similar: see bottle comment. Code bad. |
8 | A | 6 | 20111117 | 063600 | 2011-11-17T06:36:00.00Z | 35.41771 | -66.51712 | SIOR | 1 | 6768 | no3 | 4 | mcj | deepest and shallowest (1500m) nutrient values similar: see bottle comment. Code bad. |
8 | A | 6 | 20111117 | 063600 | 2011-11-17T06:36:00.00Z | 35.41771 | -66.51712 | SIOR | 1 | 6768 | o2 | 4 | mcj | deepest o2 value aligns with CTDO; but o2 draw temp high and deepest and shallowest o2 values match; see bottle comment. Code bad. |
8 | A | 6 | 20111117 | 063600 | 2011-11-17T06:36:00.00Z | 35.41771 | -66.51712 | SIOR | 1 | 6768 | po4 | 4 | mcj | deepest and shallowest (1500m) nutrient values similar: see bottle comment. Code bad. |
8 | A | 6 | 20111117 | 063600 | 2011-11-17T06:36:00.00Z | 35.41771 | -66.51712 | SIOR | 1 | 6768 | salt | 4 | mcj | deepest salt value is +0.11 vs CTDS: matches 1500m salt value; see bottle comment. Code bad. |
8 | A | 6 | 20111117 | 063600 | 2011-11-17T06:36:00.00Z | 35.41771 | -66.51712 | SIOR | 1 | 6768 | sio3 | 4 | mcj | deepest and shallowest (1500m) nutrient values similar: see bottle comment. Code bad. |
8 | A | 6 | 20111117 | 063600 | 2011-11-17T06:36:00.00Z | 35.41771 | -66.51712 | SIOR | 4 | 6771 | po4 | 3 | mtm | value is high and does not match GT-C cast values for similar depth |
8 | A | 6 | 20111117 | 063600 | 2011-11-17T06:36:00.00Z | 35.41771 | -66.51712 | SIOR | 4 | 6771 | salt | 4 | cms | Bottle salt high for CTD trend in low gradient region; code questionable. |
8 | A | 6 | 20111117 | 063600 | 2011-11-17T06:36:00.00Z | 35.41771 | -66.51712 | SIOR | 7 | 6774 | bot | 3 | slog | Bottle 7 bottom cap jarred loose during recovery; top cap did not seal: shut on bottle 6 lanyard line. Broke pressure seal and allowed leaking. |
8 | A | 6 | 20111117 | 063600 | 2011-11-17T06:36:00.00Z | 35.41771 | -66.51712 | SIOR | 7 | 6774 | no2 | 4 | mtm | water likely not from proper depth due to lanyard issue |
8 | A | 6 | 20111117 | 063600 | 2011-11-17T06:36:00.00Z | 35.41771 | -66.51712 | SIOR | 7 | 6774 | no3 | 4 | mtm | value low; water likely not from proper depth due to lanyard issue |
8 | A | 6 | 20111117 | 063600 | 2011-11-17T06:36:00.00Z | 35.41771 | -66.51712 | SIOR | 7 | 6774 | o2 | 4 | cms | Bottle o2 value low; leaky niskin. Code bad. |
8 | A | 6 | 20111117 | 063600 | 2011-11-17T06:36:00.00Z | 35.41771 | -66.51712 | SIOR | 7 | 6774 | po4 | 4 | mtm | value low; water likely not from proper depth due to lanyard issue |
8 | A | 6 | 20111117 | 063600 | 2011-11-17T06:36:00.00Z | 35.41771 | -66.51712 | SIOR | 7 | 6774 | salt | 4 | mcj | salt value high; leaky niskin. Code bad. |
8 | A | 6 | 20111117 | 063600 | 2011-11-17T06:36:00.00Z | 35.41771 | -66.51712 | SIOR | 7 | 6774 | sio3 | 4 | mtm | value low; water likely not from proper depth due to lanyard issue |
8 | A | 6 | 20111117 | 063600 | 2011-11-17T06:36:00.00Z | 35.41771 | -66.51712 | SIOR | 8 | 6775 | salt | 4 | cms | Bottle salt value does not agree with CTD profile. Analyst: SaltBtl_32: thimble came out with cap; readings very erratic; probable contamination. |
10 | B | 1 | 20111119 | 184332 | 2011-11-19T18:43:31.80Z | 31.75211 | -64.17199 | GT-C | 14 | 6799 | no2nm | 3 | web | out of calibration range; but within working range |
10 | B | 1 | 20111119 | 184332 | 2011-11-19T18:43:31.80Z | 31.75211 | -64.17199 | GT-C | 14 | 6799 | po4nm | 5 | web | out of working range |
10 | B | 1 | 20111119 | 184332 | 2011-11-19T18:43:31.80Z | 31.75211 | -64.17199 | GT-C | 16 | 6797 | po4nm | 5 | web | out of working range |
10 | B | 1 | 20111119 | 184332 | 2011-11-19T18:43:31.80Z | 31.75211 | -64.17199 | GT-C | 18 | 6795 | po4nm | 5 | web | out of working range |
10 | B | 2 | 20111119 | 202600 | 2011-11-19T20:26:00.00Z | 31.75653 | -64.17856 | SIOR | 2 | 6815 | reft | 3 | mcj | SBE35T -0.015 vs CTDT; unstable SBE35T reading; in a gradient. Code questionable. |
10 | B | 4 | 20111120 | 050624 | 2011-11-20T05:06:24.00Z | 31.74948 | -64.16764 | SIOR | 5 | 6838 | bot | 3 | slog | bottom cap leak after sampling started; could not make it stop. Samples taken asap; shutting vent between samples. A piece of plastic debris was later found in lower cap o-ring. |
10 | B | 4 | 20111120 | 050624 | 2011-11-20T05:06:24.00Z | 31.74948 | -64.16764 | SIOR | 9 | 6842 | no2 | 3 | mtm | value high compared to casts at overlapping depths; no analytical errors noted |
10 | B | 5 | 20111120 | 085005 | 2011-11-20T08:50:04.80Z | 31.74708 | -64.17316 | GT-C | 8 | 6867 | bot | 4 | mcj | Nutrients and salinity indicate GoFlo 25 apparently closed at a shallower depth than tripped. GoFlo 25 changed out after station 14. |
10 | B | 5 | 20111120 | 085005 | 2011-11-20T08:50:04.80Z | 31.74708 | -64.17316 | GT-C | 8 | 6867 | no2 | 4 | mtm | other nutrient values low and do not match sample 507; GoFlo did not close where expected; code nutrients bad. |
10 | B | 5 | 20111120 | 085005 | 2011-11-20T08:50:04.80Z | 31.74708 | -64.17316 | GT-C | 8 | 6867 | no3 | 4 | mtm | value low and does not match sample 507 (tripped at same depth); GoFlo did not close where expected; code nutrients bad. |
10 | B | 5 | 20111120 | 085005 | 2011-11-20T08:50:04.80Z | 31.74708 | -64.17316 | GT-C | 8 | 6867 | po4 | 4 | mtm | value low and does not match sample 507 (tripped at same depth); GoFlo did not close where expected; code nutrients bad. |
10 | B | 5 | 20111120 | 085005 | 2011-11-20T08:50:04.80Z | 31.74708 | -64.17316 | GT-C | 8 | 6867 | salt | 4 | mcj | Deep salinity value +0.02 vs CTDS and sample from 507; GoFlo did not close where expected; code salinity bad. |
10 | B | 5 | 20111120 | 085005 | 2011-11-20T08:50:04.80Z | 31.74708 | -64.17316 | GT-C | 8 | 6867 | sio3 | 4 | mtm | value low and does not match sample 507 (tripped at same depth); GoFlo did not close where expected; code nutrients bad. |
10 | B | 6 | 20111120 | 115503 | 2011-11-20T11:55:03.00Z | 31.73678 | -64.19024 | SIOR | 5 | 6879 | bot | 2 | clog | Niskin s/n 5 replaced from spares before cast (using Niskin s/n 15). |
10 | B | 6 | 20111120 | 115503 | 2011-11-20T11:55:03.00Z | 31.73678 | -64.19024 | SIOR | 9 | 6883 | reft | 3 | mcj | SBE35T +0.06/+0.05 vs CTDT1/CTDT2; very unstable SBE35T reading; in a gradient. Code questionable. |
10 | B | 8 | 20111121 | 021456 | 2011-11-21T02:14:55.80Z | 31.747 | -64.16928 | SIOR | 4 | 6849 | salt | 2 | cms | Bottle salt value agrees with CTD values and water column trend; code acceptable. Analyst: SaltBtl_16: thimble came out with cap - readings erratic. |
10 | B | 8 | 20111121 | 021456 | 2011-11-21T02:14:55.80Z | 31.747 | -64.16928 | SIOR | 11 | 6901 | salt | 2 | cms | Bottle salt value agrees with CTD values and water column trend; code acceptable. Analyst: SaltBtl_23: thimble came out with cap; readings erratic. |
10 | B | 9 | 20111121 | 034027 | 2011-11-21T03:40:27.00Z | 31.747 | -64.17074 | GT-C | 3 | -999 | bot | 3 | clog | GoFlo 37 leaking on board. |
10 | B | 9 | 20111121 | 034027 | 2011-11-21T03:40:27.00Z | 31.747 | -64.17074 | GT-C | 4 | -999 | bot | 3 | clog | GoFlo 35 leaking on board. |
10 | B | 10 | 20111121 | 061343 | 2011-11-21T06:13:43.20Z | 31.75172 | -64.16475 | SIOR | 9 | 6923 | salt | 3 | mcj | Deep salinity value +0.007 vs CTDS; code questionable. |
10 | B | 11 | 20111121 | 090024 | 2011-11-21T09:00:24.00Z | 31.752 | -64.16419 | GT-C | 14 | 6939 | salt | 2 | cms | Bottle salt value agrees with CTD values and water column trend; code acceptable. Analyst: SaltBtl_11: thimble came out with cap; probable contamination. |
10 | B | 12 | 20111121 | 112148 | 2011-11-21T11:21:48.00Z | 31.75097 | -64.16602 | SIOR | 2 | 6928 | o2 | 2 | slog | Particulates in o2 flask. |
10 | B | 12 | 20111121 | 112148 | 2011-11-21T11:21:48.00Z | 31.75097 | -64.16602 | SIOR | 11 | 6961 | reft | 3 | mcj | SBE35T -0.065/-0.060 vs CTDT1/CTDT2; unstable SBE35T reading. Code questionable. |
11 | B | 1 | 20111122 | 071423 | 2011-11-22T07:14:22.80Z | 30.81967 | -60.77998 | GT-C | 13 | 6976 | no2nm | 3 | web | out of calibration range; but within working range |
11 | B | 1 | 20111122 | 071423 | 2011-11-22T07:14:22.80Z | 30.81967 | -60.77998 | GT-C | 13 | 6976 | po4nm | 5 | web | out of working range |
11 | B | 1 | 20111122 | 071423 | 2011-11-22T07:14:22.80Z | 30.81967 | -60.77998 | GT-C | 15 | 6974 | no2nm | 3 | web | out of calibration range; but within working range |
11 | B | 1 | 20111122 | 071423 | 2011-11-22T07:14:22.80Z | 30.81967 | -60.77998 | GT-C | 15 | 6974 | po4nm | 5 | web | out of working range |
11 | B | 1 | 20111122 | 071423 | 2011-11-22T07:14:22.80Z | 30.81967 | -60.77998 | GT-C | 17 | 6972 | no2nm | 3 | web | out of calibration range; but within working range |
11 | B | 1 | 20111122 | 071423 | 2011-11-22T07:14:22.80Z | 30.81967 | -60.77998 | GT-C | 17 | 6972 | po4nm | 5 | web | out of working range |
11 | B | 1 | 20111122 | 071423 | 2011-11-22T07:14:22.80Z | 30.81967 | -60.77998 | GT-C | 19 | 6970 | salt | 4 | cms | Bottle salt value matches duplicate bottle trip 20 and bottle values for trips 21 & 22. Does not match CTD value for 120db. Probable mis-sample; code questionable. |
11 | B | 1 | 20111122 | 071423 | 2011-11-22T07:14:22.80Z | 30.81967 | -60.77998 | GT-C | 20 | 6969 | salt | 4 | cms | Bottle salt value matches duplicate bottle trip 19 and bottle values for trips 21 & 22. Does not match CTD value for 120db. Probable mis-sample; code questionable. |
11 | B | 2 | 20111122 | 090415 | 2011-11-22T09:04:15.00Z | 30.82354 | -60.78694 | SIOR | 13 | 7003 | salt | 2 | rlp | Analyst: Salt 13 is surface pumped sample associated with cast |
12 | B | 1 | 20111123 | 053658 | 2011-11-23T05:36:58.20Z | 29.69995 | -56.81655 | GT-C | 14 | 7015 | no2nm | 3 | web | out of calibration range; but within working range |
12 | B | 1 | 20111123 | 053658 | 2011-11-23T05:36:58.20Z | 29.69995 | -56.81655 | GT-C | 14 | 7015 | po4nm | 5 | web | out of working range |
12 | B | 1 | 20111123 | 053658 | 2011-11-23T05:36:58.20Z | 29.69995 | -56.81655 | GT-C | 16 | 7013 | no2nm | 3 | web | out of calibration range; but within working range |
12 | B | 1 | 20111123 | 053658 | 2011-11-23T05:36:58.20Z | 29.69995 | -56.81655 | GT-C | 16 | 7013 | po4nm | 5 | web | out of working range |
12 | B | 1 | 20111123 | 053658 | 2011-11-23T05:36:58.20Z | 29.69995 | -56.81655 | GT-C | 18 | 7011 | po4nm | 5 | web | out of working range |
12 | B | 1 | 20111123 | 053658 | 2011-11-23T05:36:58.20Z | 29.69995 | -56.81655 | GT-C | 19 | 7010 | salt | 4 | cms | Bottle salt value matches duplicate bottle trip #20 and bottle values for trips 23 & 24. Does not match CTD value for 100db. Suggest sampled from wrong bottle; code questionable. |
12 | B | 1 | 20111123 | 053658 | 2011-11-23T05:36:58.20Z | 29.69995 | -56.81655 | GT-C | 20 | 7009 | salt | 4 | cms | Bottle salt value matches duplicate bottle trip #19 and bottle values for trips 23 & 24. Does not match CTD value for 100db. Suggest sampled from wrong bottle; code questionable. |
12 | B | 2 | 20111123 | 071711 | 2011-11-23T07:17:10.80Z | 29.69997 | -56.81702 | SIOR | 10 | 7039 | reft | 3 | mcj | SBE35T -0.06 vs CTDT; very unstable SBE35T reading; in a gradient. Code questionable. |
12 | B | 4 | 20111123 | 160247 | 2011-11-23T16:02:46.80Z | 29.69998 | -56.81705 | SIOR | 3 | 7052 | salt | 3 | cms | Bottle salt value low vs. CTD in low gradient region; but falls with in water column trend; code questionable. |
12 | B | 4 | 20111123 | 160247 | 2011-11-23T16:02:46.80Z | 29.69998 | -56.81705 | SIOR | 6 | 7055 | salt | 3 | cms | Bottle salt value low vs. CTD in low gradient region; but falls with in water column trend; code questionable. |
12 | B | 4 | 20111123 | 160247 | 2011-11-23T16:02:46.80Z | 29.69998 | -56.81705 | SIOR | 12 | 7061 | salt | 2 | cms | Bottle value agrees closely with CTD; water column trend and adjacent parameters; code acceptable. ANALYST: Thimble came out with cap; probably contamination. |
12 | B | 5 | 20111123 | 204835 | 2011-11-23T20:48:34.80Z | 29.69998 | -56.81705 | GT-C | 5 | 7081 | salt | 4 | cms | Bottle salt value high for CTD value and 506 at same depth. Value agrees with 507. Probable mis-sample; code questionable. |
12 | B | 5 | 20111123 | 204835 | 2011-11-23T20:48:34.80Z | 29.69998 | -56.81705 | GT-C | 7 | 7079 | salt | 2 | rlp | Bottle salt value agrees with CTD; water column and adjacent parameters; code acceptable. ANALYST: Thimble came out with cap; very wet; readings suspect. |
12 | B | 5 | 20111123 | 204835 | 2011-11-23T20:48:34.80Z | 29.69998 | -56.81705 | GT-C | 8 | 7078 | bot | 4 | mcj | Nutrients and salinity indicate GoFlo 25 apparently closed at a shallower depth than tripped. GoFlo 25 changed out after station 14. |
12 | B | 5 | 20111123 | 204835 | 2011-11-23T20:48:34.80Z | 29.69998 | -56.81705 | GT-C | 8 | 7078 | no2 | 4 | mtm | other nutrient values low and do not match sample 507; GoFlo did not close where expected; code nutrients bad. |
12 | B | 5 | 20111123 | 204835 | 2011-11-23T20:48:34.80Z | 29.69998 | -56.81705 | GT-C | 8 | 7078 | no3 | 4 | mtm | value low and does not match sample 507 (tripped at same depth); GoFlo did not close where expected; code nutrients bad. |
12 | B | 5 | 20111123 | 204835 | 2011-11-23T20:48:34.80Z | 29.69998 | -56.81705 | GT-C | 8 | 7078 | po4 | 4 | mtm | value low and does not match sample 507 (tripped at same depth); GoFlo did not close where expected; code nutrients bad. |
12 | B | 5 | 20111123 | 204835 | 2011-11-23T20:48:34.80Z | 29.69998 | -56.81705 | GT-C | 8 | 7078 | salt | 4 | mcj | Deep salinity value +0.025 vs CTDS and sample from 507; GoFlo did not close where expected; code salinity bad. |
12 | B | 5 | 20111123 | 204835 | 2011-11-23T20:48:34.80Z | 29.69998 | -56.81705 | GT-C | 8 | 7078 | sio3 | 4 | mtm | value low and does not match sample 507 (tripped at same depth); GoFlo did not close where expected; code nutrients bad. |
12 | B | 5 | 20111123 | 204835 | 2011-11-23T20:48:34.80Z | 29.69998 | -56.81705 | GT-C | 21 | 7065 | salt | 2 | cms | Bottle value agrees closely with CTD; water column trend and adjacent parameters; code acceptable. ANALYST: Exactly at 2.00000 ratio; would not hold stable reading on either; adjacent suppression setting |
12 | B | 6 | 20111123 | 234146 | 2011-11-23T23:41:46.20Z | 29.70004 | -56.81703 | SIOR | 13 | 7098 | salt | 2 | cms | Bottle value agrees closely with CTD; water column trend and adjacent parameters; code acceptable. ANALYST: Is surface pumped sample associated with cast. |
13 | B | 1 | 20111125 | 181722 | 2011-11-25T18:17:22.20Z | 28.64321 | -53.22249 | GT-C | 13 | 7181 | no2nm | 3 | web | out of calibration range; but within working range |
13 | B | 1 | 20111125 | 181722 | 2011-11-25T18:17:22.20Z | 28.64321 | -53.22249 | GT-C | 13 | 7181 | po4nm | 5 | web | out of working range |
13 | B | 1 | 20111125 | 181722 | 2011-11-25T18:17:22.20Z | 28.64321 | -53.22249 | GT-C | 15 | 7179 | no2nm | 3 | web | out of calibration range; but within working range |
13 | B | 1 | 20111125 | 181722 | 2011-11-25T18:17:22.20Z | 28.64321 | -53.22249 | GT-C | 15 | 7179 | po4nm | 5 | web | out of working range |
13 | B | 1 | 20111125 | 181722 | 2011-11-25T18:17:22.20Z | 28.64321 | -53.22249 | GT-C | 17 | 7177 | no2nm | 3 | web | out of calibration range; but within working range |
13 | B | 1 | 20111125 | 181722 | 2011-11-25T18:17:22.20Z | 28.64321 | -53.22249 | GT-C | 17 | 7177 | po4nm | 5 | web | out of working range |
13 | B | 1 | 20111125 | 181722 | 2011-11-25T18:17:22.20Z | 28.64321 | -53.22249 | GT-C | 19 | 7175 | po4nm | 5 | web | out of working range |
13 | B | 1 | 20111125 | 181722 | 2011-11-25T18:17:22.20Z | 28.64321 | -53.22249 | GT-C | 21 | 7173 | no3nm | 3 | web | out of calibration range; but within working range |
13 | B | 1 | 20111125 | 181722 | 2011-11-25T18:17:22.20Z | 28.64321 | -53.22249 | GT-C | 24 | 7170 | bot | 2 | slog | flow rate too slow through membrane; Hg_Total sample taken through Acropak. |
13 | B | 2 | 20111125 | 194322 | 2011-11-25T19:43:22.20Z | 28.64405 | -53.22582 | SIOR | 13 | 7206 | salt | 2 | rlp | ANALYST: 13 is surface pumped sample associated with cast. |
14 | B | 1 | 20111126 | 141347 | 2011-11-26T14:13:46.80Z | 27.58305 | -49.63299 | GT-C | 14 | 7219 | no2nm | 3 | web | out of calibration range; but within working range |
14 | B | 1 | 20111126 | 141347 | 2011-11-26T14:13:46.80Z | 27.58305 | -49.63299 | GT-C | 14 | 7219 | po4nm | 5 | web | out of working range |
14 | B | 1 | 20111126 | 141347 | 2011-11-26T14:13:46.80Z | 27.58305 | -49.63299 | GT-C | 16 | 7217 | po4nm | 5 | web | out of working range |
14 | B | 1 | 20111126 | 141347 | 2011-11-26T14:13:46.80Z | 27.58305 | -49.63299 | GT-C | 18 | 7215 | no3nm | 3 | web | out of calibration range; but within working range |
14 | B | 1 | 20111126 | 141347 | 2011-11-26T14:13:46.80Z | 27.58305 | -49.63299 | GT-C | 22 | 7211 | salt | 3 | cms | Bottle value does not agree with 121 or CTD in upper 100m; code questionable. |
14 | B | 1 | 20111126 | 141347 | 2011-11-26T14:13:46.80Z | 27.58305 | -49.63299 | GT-C | 24 | 7209 | bot | 2 | slog | flow rate too slow through membrane; Hg_Total sample taken through Acropak. |
14 | B | 2 | 20111126 | 153057 | 2011-11-26T15:30:57.00Z | 27.58305 | -49.63299 | SIOR | 10 | 7242 | reft | 3 | mcj | SBE35T +0.01 vs CTDT; unstable SBE35T reading; in a gradient. Code questionable. |
14 | B | 2 | 20111126 | 153057 | 2011-11-26T15:30:57.00Z | 27.58305 | -49.63299 | SIOR | 11 | 7243 | reft | 3 | mcj | SBE35T +0.024 vs CTDT; unstable SBE35T reading; in a gradient. Code questionable. |
14 | B | 4 | 20111126 | 223747 | 2011-11-26T22:37:46.80Z | 27.58304 | -49.63298 | SIOR | 3 | 7259 | salt | 4 | cms | Bottle value high for CTD in transition region. Code bad due to analyst remark. ANALYST: thimble came out with cap - probably contamination. |
14 | B | 4 | 20111126 | 223747 | 2011-11-26T22:37:46.80Z | 27.58304 | -49.63298 | SIOR | 9 | 7265 | o2 | 2 | cms | OT 0.5538 Abnormal finish first titrate. No slope. After back titration good curve. Bottle value appears good. |
14 | B | 5 | 20111127 | 010712 | 2011-11-27T01:07:12.00Z | 27.58305 | -49.63297 | GT-C | 2 | 7292 | salt | 3 | cms | Bottle value does not match 501. Value high for low gradient region; code questionable. |
14 | B | 5 | 20111127 | 010712 | 2011-11-27T01:07:12.00Z | 27.58305 | -49.63297 | GT-C | 8 | 7286 | bot | 4 | mcj | Nutrients and salinity indicate GoFlo 25 apparently closed at a shallower depth than tripped. GoFlo 25 changed out after station 14. |
14 | B | 5 | 20111127 | 010712 | 2011-11-27T01:07:12.00Z | 27.58305 | -49.63297 | GT-C | 8 | 7286 | no2 | 4 | mtm | other nutrient values low and do not match sample 507; GoFlo did not close where expected; code nutrients bad. |
14 | B | 5 | 20111127 | 010712 | 2011-11-27T01:07:12.00Z | 27.58305 | -49.63297 | GT-C | 8 | 7286 | no3 | 4 | mtm | value low and does not match sample 507 (tripped at same depth); GoFlo did not close where expected; code nutrients bad. |
14 | B | 5 | 20111127 | 010712 | 2011-11-27T01:07:12.00Z | 27.58305 | -49.63297 | GT-C | 8 | 7286 | po4 | 4 | mtm | value low and does not match sample 507 (tripped at same depth); GoFlo did not close where expected; code nutrients bad. |
14 | B | 5 | 20111127 | 010712 | 2011-11-27T01:07:12.00Z | 27.58305 | -49.63297 | GT-C | 8 | 7286 | salt | 4 | mcj | Deep salinity value +0.02 vs CTDS and sample from 507; GoFlo did not close where expected; code salinity bad. |
14 | B | 5 | 20111127 | 010712 | 2011-11-27T01:07:12.00Z | 27.58305 | -49.63297 | GT-C | 8 | 7286 | sio3 | 4 | mtm | value low and does not match sample 507 (tripped at same depth); GoFlo did not close where expected; code nutrients bad. |
14 | B | 5 | 20111127 | 010712 | 2011-11-27T01:07:12.00Z | 27.58305 | -49.63297 | GT-C | 11 | 7283 | salt | 2 | cms | Bottle values agree with other salts and with CTD; code acceptable. ANALYST: Salts 11 and 13 reversed in case. Assumed 11 was drawn first and put back in numerical sequence; Salts 11; 12; 13; 14 appear to be the correct numerical sequence. |
14 | B | 5 | 20111127 | 010712 | 2011-11-27T01:07:12.00Z | 27.58305 | -49.63297 | GT-C | 12 | 7282 | salt | 2 | cms | Bottle values agree with other salts and with CTD; code acceptable. ANALYST: Salts 11 and 13 reversed in case. Assumed 11 was drawn first and put back in numerical sequence; Salts 11; 12; 13; 14 appear to be the correct numerical sequence. |
14 | B | 5 | 20111127 | 010712 | 2011-11-27T01:07:12.00Z | 27.58305 | -49.63297 | GT-C | 13 | 7281 | salt | 2 | cms | Bottle values agree with other salts and with CTD; code acceptable. ANALYST: Salts 11 and 13 reversed in case. Assumed 11 was drawn first and put back in numerical sequence; Salts 11; 12; 13; 14 appear to be the correct numerical sequence. |
14 | B | 5 | 20111127 | 010712 | 2011-11-27T01:07:12.00Z | 27.58305 | -49.63297 | GT-C | 14 | 7280 | salt | 2 | cms | Bottle values agree with other salts and with CTD; code acceptable. ANALYST: Salts 11 and 13 reversed in case. Assumed 11 was drawn first and put back in numerical sequence; Salts 11; 12; 13; 14 appear to be the correct numerical sequence. |
14 | B | 6 | 20111127 | 042741 | 2011-11-27T04:27:40.80Z | 27.58305 | -49.63298 | SIOR | 11 | 7304 | bot | 2 | slog | vent possibly not shut tight. |
14 | B | 6 | 20111127 | 042741 | 2011-11-27T04:27:40.80Z | 27.58305 | -49.63298 | SIOR | 12 | 7305 | salt | 2 | cms | Bottle value agrees with CTD profile; code acceptable. ANALYST: thimble came out with cap; possible contamination. |
15 | B | 1 | 20111128 | 044353 | 2011-11-28T04:43:52.80Z | 26.85758 | -47.2301 | GT-C | 8 | 7334 | bot | 4 | slog | GoFlo 37: leaking badly from bottom valve until re-snapped shut. |
15 | B | 1 | 20111128 | 044353 | 2011-11-28T04:43:52.80Z | 26.85758 | -47.2301 | GT-C | 12 | 7330 | bot | 2 | slog | GoFlo 18: flow through membrane just stopped; is if membrane were fully loaded. |
15 | B | 1 | 20111128 | 044353 | 2011-11-28T04:43:52.80Z | 26.85758 | -47.2301 | GT-C | 13 | 7329 | no2nm | 3 | web | out of calibration range; but within working range |
15 | B | 1 | 20111128 | 044353 | 2011-11-28T04:43:52.80Z | 26.85758 | -47.2301 | GT-C | 13 | 7329 | po4nm | 5 | web | out of working range |
15 | B | 1 | 20111128 | 044353 | 2011-11-28T04:43:52.80Z | 26.85758 | -47.2301 | GT-C | 15 | 7327 | no2nm | 3 | web | out of calibration range; but within working range |
15 | B | 1 | 20111128 | 044353 | 2011-11-28T04:43:52.80Z | 26.85758 | -47.2301 | GT-C | 15 | 7327 | po4nm | 5 | web | out of working range |
15 | B | 1 | 20111128 | 044353 | 2011-11-28T04:43:52.80Z | 26.85758 | -47.2301 | GT-C | 17 | 7325 | no2nm | 3 | web | out of calibration range; but within working range |
15 | B | 1 | 20111128 | 044353 | 2011-11-28T04:43:52.80Z | 26.85758 | -47.2301 | GT-C | 17 | 7325 | po4nm | 5 | web | out of working range |
15 | B | 1 | 20111128 | 044353 | 2011-11-28T04:43:52.80Z | 26.85758 | -47.2301 | GT-C | 19 | 7323 | no2nm | 5 | web | out of working range |
15 | B | 1 | 20111128 | 044353 | 2011-11-28T04:43:52.80Z | 26.85758 | -47.2301 | GT-C | 19 | 7323 | po4nm | 5 | web | out of working range |
15 | B | 1 | 20111128 | 044353 | 2011-11-28T04:43:52.80Z | 26.85758 | -47.2301 | GT-C | 20 | 7322 | po4nm | 5 | web | out of working range |
15 | B | 1 | 20111128 | 044353 | 2011-11-28T04:43:52.80Z | 26.85758 | -47.2301 | GT-C | 21 | 7321 | no3nm | 3 | web | out of calibration range; but within working range |
16 | B | 1 | 20111128 | 212833 | 2011-11-28T21:28:33.00Z | 26.13683 | -44.82622 | GT-C | 12 | 7358 | bot | 3 | slog | GoFlo 9: slow leak from bottom; coming from base of valve stem (where gray stem base meets GoFlo cylinder body). Removed from use; send to GO for repair. |
16 | B | 1 | 20111128 | 212833 | 2011-11-28T21:28:33.00Z | 26.13683 | -44.82622 | GT-C | 12 | 7358 | no3 | 3 | mtm | value high and does not match duplicate 111 |
16 | B | 4 | 20111129 | 133342 | 2011-11-29T13:33:42.00Z | 26.13685 | -44.82621 | SIOR | 6 | 7395 | salt | 2 | cms | Bottle value higher than general trend vs. CTD; however still with in acceptable limits. ANALYST: Salt 6; Thimble came out with cap; readings erratic. |
16 | B | 5 | 20111129 | 162632 | 2011-11-29T16:26:31.80Z | 26.13685 | -44.82621 | GT-C | 2 | 7424 | bot | 2 | clog | GoFlo 12: sample valve O-ring and washer were installed backwards. Fixed (before cast). |
16 | B | 6 | 20111129 | 212505 | 2011-11-29T21:25:04.80Z | 26.13576 | -44.8264 | SIOR | 13 | 7439 | salt | 2 | rlp | 0013: Salt/niskin 13; surface pumped sample associated with cast. |
16 | B | 9 | 20111130 | 051518 | 2011-11-30T05:15:18.00Z | 26.13686 | -44.82621 | GT-C | 14 | 7471 | no2nm | 3 | web | out of calibration range; but within working range |
16 | B | 9 | 20111130 | 051518 | 2011-11-30T05:15:18.00Z | 26.13686 | -44.82621 | GT-C | 14 | 7471 | po4nm | 5 | web | out of working range |
16 | B | 9 | 20111130 | 051518 | 2011-11-30T05:15:18.00Z | 26.13686 | -44.82621 | GT-C | 16 | 7469 | po4nm | 5 | web | out of working range |
16 | B | 9 | 20111130 | 051518 | 2011-11-30T05:15:18.00Z | 26.13686 | -44.82621 | GT-C | 18 | 7466 | no3nm | 3 | web | out of calibration range; but within working range |
16 | B | 9 | 20111130 | 051518 | 2011-11-30T05:15:18.00Z | 26.13686 | -44.82621 | GT-C | 18 | 7466 | po4nm | 5 | web | out of working range |
16 | B | 11 | 20111130 | 101223 | 2011-11-30T10:12:22.80Z | 26.13687 | -44.8262 | SIOR | 7 | 7503 | salt | 2 | cms | Bottle salt values agree with CTD trend. ANALYST: SaltBtls 19-21 (samps.1107;1108;1110) placed in crate in wrong order; not noticed until SaltBtl 19 (samp.1110) was being analyzed. Samples collected in correct order. (Data file corrected.) |
16 | B | 11 | 20111130 | 101223 | 2011-11-30T10:12:22.80Z | 26.13687 | -44.8262 | SIOR | 8 | 7504 | salt | 2 | cms | Bottle salt values agree with CTD trend. ANALYST: SaltBtls 19-21 (samps.1107;1108;1110) placed in crate in wrong order; not noticed until SaltBtl 19 (samp.1110) was being analyzed. Samples collected in correct order. (Data file corrected.) |
16 | B | 11 | 20111130 | 101223 | 2011-11-30T10:12:22.80Z | 26.13687 | -44.8262 | SIOR | 10 | 7505 | salt | 2 | cms | Bottle salt values agree with CTD trend. ANALYST: SaltBtls 19-21 placed in crate in wrong order; not noticed until SaltBtl 19 (samp.1110) was being analyzed. Samples collected in correct order. (Data file corrected.) |
17 | B | 1 | 20111201 | 003145 | 2011-12-01T00:31:45.00Z | 25.14221 | -42.52199 | GT-C | 3 | 7533 | salt | 2 | cms | Bottle value matches 104 and CTD profile. Code acceptable. ANALYST: Salt 3; thimble came out with cap; readings erratic. |
17 | B | 1 | 20111201 | 003145 | 2011-12-01T00:31:45.00Z | 25.14221 | -42.52199 | GT-C | 7 | 7529 | salt | 2 | cms | Bottle value high for 106 and for CTD; however falls with in acceptable limits for high gradient region. Code acceptable. ANALYST: Salt 7; readings indicate contamination but no obvious cause. |
17 | B | 1 | 20111201 | 003145 | 2011-12-01T00:31:45.00Z | 25.14221 | -42.52199 | GT-C | 13 | 7523 | no2nm | 3 | web | out of calibration range; but within working range |
17 | B | 1 | 20111201 | 003145 | 2011-12-01T00:31:45.00Z | 25.14221 | -42.52199 | GT-C | 13 | 7523 | po4nm | 5 | web | out of working range |
17 | B | 1 | 20111201 | 003145 | 2011-12-01T00:31:45.00Z | 25.14221 | -42.52199 | GT-C | 15 | 7521 | no2nm | 3 | web | out of calibration range; but within working range |
17 | B | 1 | 20111201 | 003145 | 2011-12-01T00:31:45.00Z | 25.14221 | -42.52199 | GT-C | 15 | 7521 | po4nm | 5 | web | out of working range |
17 | B | 1 | 20111201 | 003145 | 2011-12-01T00:31:45.00Z | 25.14221 | -42.52199 | GT-C | 16 | 7520 | salt | 3 | cms | Bottle value does not match 115 or CTD profile. Code questionable. |
17 | B | 1 | 20111201 | 003145 | 2011-12-01T00:31:45.00Z | 25.14221 | -42.52199 | GT-C | 17 | 7519 | no2nm | 3 | web | out of calibration range; but within working range |
17 | B | 1 | 20111201 | 003145 | 2011-12-01T00:31:45.00Z | 25.14221 | -42.52199 | GT-C | 17 | 7519 | po4nm | 5 | web | out of working range |
17 | B | 1 | 20111201 | 003145 | 2011-12-01T00:31:45.00Z | 25.14221 | -42.52199 | GT-C | 19 | 7517 | no3nm | 3 | web | out of calibration range; but within working range |
17 | B | 1 | 20111201 | 003145 | 2011-12-01T00:31:45.00Z | 25.14221 | -42.52199 | GT-C | 19 | 7517 | po4nm | 5 | web | out of working range |
17 | B | 2 | 20111201 | 015849 | 2011-12-01T01:58:49.20Z | 25.14128 | -42.52194 | SIOR | 13 | 7548 | salt | 2 | rlp | ANALYST: Salt 13 is surface pump sample associated with cast. |
18 | B | 1 | 20111201 | 163513 | 2011-12-01T16:35:13.20Z | 24.1497 | -40.21787 | GT-C | 14 | 7561 | no2nm | 3 | web | out of calibration range; but within working range |
18 | B | 1 | 20111201 | 163513 | 2011-12-01T16:35:13.20Z | 24.1497 | -40.21787 | GT-C | 14 | 7561 | po4nm | 5 | web | out of working range |
18 | B | 1 | 20111201 | 163513 | 2011-12-01T16:35:13.20Z | 24.1497 | -40.21787 | GT-C | 16 | 7559 | po4nm | 5 | web | out of working range |
18 | B | 2 | 20111201 | 175152 | 2011-12-01T17:51:52.20Z | 24.14972 | -40.21786 | SIOR | 7 | 7581 | reft | 3 | cms | SBE35 and CTDT2 vs CTDT1 very different through high gradient. Code questionable. |
18 | B | 2 | 20111201 | 175152 | 2011-12-01T17:51:52.20Z | 24.14972 | -40.21786 | SIOR | 7 | 7581 | salt | 3 | cms | Bottle salt value unstable through high gradient. Code questionable. |
18 | B | 5 | 20111202 | 045938 | 2011-12-02T04:59:37.80Z | 24.15003 | -40.21706 | GT-C | 3 | 7629 | salt | 3 | cms | Bottle salt value high for low gradient region. Code questionable. |
18 | B | 5 | 20111202 | 045938 | 2011-12-02T04:59:37.80Z | 24.15003 | -40.21706 | GT-C | 9 | 7623 | salt | 3 | cms | Bottle salt value high for low gradient region. Code questionable. |
18 | B | 5 | 20111202 | 045938 | 2011-12-02T04:59:37.80Z | 24.15003 | -40.21706 | GT-C | 11 | 7621 | salt | 3 | cms | Bottle salt value high for low gradient region. Code questionable. |
18 | B | 5 | 20111202 | 045938 | 2011-12-02T04:59:37.80Z | 24.15003 | -40.21706 | GT-C | 14 | 7618 | salt | 2 | cms | Bottle value matches CTD closely for low gradient region; code acceptable. ANALYST: samp 23; thimble came out with cap; probable contamination. |
18 | B | 5 | 20111202 | 045938 | 2011-12-02T04:59:37.80Z | 24.15003 | -40.21706 | GT-C | 15 | 7617 | salt | 2 | cms | Bottle value matches CTD closely for low gradient region; code acceptable. ANALYST: 0016: Salts 15 and 16 reversed in crate; put in numerical sequence before running. Readings still look out of place if are in fact replicate samples from same depth niskins. |
18 | B | 5 | 20111202 | 045938 | 2011-12-02T04:59:37.80Z | 24.15003 | -40.21706 | GT-C | 16 | 7616 | salt | 2 | cms | Bottle value matches CTD closely for low gradient region; code acceptable. ANALYST: 0016: Salts 15 and 16 reversed in crate; put in numerical sequence before running. Readings still look out of place if are in fact replicate samples from same depth niskins. |
18 | B | 6 | 20111202 | 083230 | 2011-12-02T08:32:30.00Z | 24.15001 | -40.21703 | SIOR | 9 | 7641 | reft | 3 | mcj | SBE35T +0.027 vs CTDT; very unstable SBE35T reading in gradient. Code questionable. |
19 | B | 1 | 20111203 | 073131 | 2011-12-03T07:31:31.20Z | 23.2429 | -38.04235 | GT-C | 3 | 7678 | salt | 2 | cms | Bottle value good vs. CTD. Code acceptable. ANALYST: Salt 3; thimble came out with cap; initial reading 13 lower than accepted readings. |
19 | B | 1 | 20111203 | 073131 | 2011-12-03T07:31:31.20Z | 23.2429 | -38.04235 | GT-C | 11 | 7670 | salt | 3 | cms | Salt bottle value does not match 112. High for CTD profile in high gradient region. Coed questionable. |
19 | B | 1 | 20111203 | 073131 | 2011-12-03T07:31:31.20Z | 23.2429 | -38.04235 | GT-C | 13 | 7668 | no2nm | 3 | web | out of calibration range; but within working range |
19 | B | 1 | 20111203 | 073131 | 2011-12-03T07:31:31.20Z | 23.2429 | -38.04235 | GT-C | 13 | 7668 | po4nm | 5 | web | out of working range |
19 | B | 1 | 20111203 | 073131 | 2011-12-03T07:31:31.20Z | 23.2429 | -38.04235 | GT-C | 15 | 7666 | no2nm | 3 | web | out of calibration range; but within working range |
19 | B | 1 | 20111203 | 073131 | 2011-12-03T07:31:31.20Z | 23.2429 | -38.04235 | GT-C | 15 | 7666 | po4nm | 5 | web | out of working range |
19 | B | 1 | 20111203 | 073131 | 2011-12-03T07:31:31.20Z | 23.2429 | -38.04235 | GT-C | 17 | 7664 | no2nm | 3 | web | out of calibration range; but within working range |
19 | B | 1 | 20111203 | 073131 | 2011-12-03T07:31:31.20Z | 23.2429 | -38.04235 | GT-C | 17 | 7664 | po4nm | 5 | web | out of working range |
19 | B | 1 | 20111203 | 073131 | 2011-12-03T07:31:31.20Z | 23.2429 | -38.04235 | GT-C | 19 | 7662 | po4nm | 5 | web | out of working range |
19 | B | 1 | 20111203 | 073131 | 2011-12-03T07:31:31.20Z | 23.2429 | -38.04235 | GT-C | 21 | 7660 | no3nm | 3 | web | out of calibration range; but within working range |
19 | B | 2 | 20111203 | 091110 | 2011-12-03T09:11:10.20Z | 23.24831 | -38.04646 | SIOR | 5 | 7685 | o2 | 2 | cms | Bottle value aligns to CTD profile; code acceptable. 1756 stopper in 1730 flask. |
19 | B | 2 | 20111203 | 091110 | 2011-12-03T09:11:10.20Z | 23.24831 | -38.04646 | SIOR | 6 | 7686 | o2 | 2 | cms | Bottle value aligns to CTD profile; code acceptable. 1730 stopper in 1756 flask. |
19 | B | 2 | 20111203 | 091110 | 2011-12-03T09:11:10.20Z | 23.24831 | -38.04646 | SIOR | 13 | 7693 | salt | 2 | mcj | Value is acceptable. ANALYST: Salt 13 is surface pumped sample associated with cast. |
20 | B | 1 | 20111203 | 221924 | 2011-12-03T22:19:24.00Z | 22.33351 | -35.86743 | GT-C | 3 | 7719 | salt | 2 | cms | Bottle salt value matches CTD profile. ANALYST: Salt 3; thimble came out with cap; readings erratic. |
20 | B | 1 | 20111203 | 221924 | 2011-12-03T22:19:24.00Z | 22.33351 | -35.86743 | GT-C | 13 | 7709 | bot | 2 | clog | Triggered empty pylon position 13 instead of 14; went back down 5m below. Data says winch went 16m back down; from 173 to 189 dbar. Database bottle trips file re-aligned post-cast. |
20 | B | 1 | 20111203 | 221924 | 2011-12-03T22:19:24.00Z | 22.33351 | -35.86743 | GT-C | 14 | 7708 | bot | 2 | clog | Triggered empty pylon position 13 instead of 14; went back down 5m below. Data says winch went 16m back down; from 173 to 189 dbar. Database bottle trips file re-aligned post-cast. |
20 | B | 1 | 20111203 | 221924 | 2011-12-03T22:19:24.00Z | 22.33351 | -35.86743 | GT-C | 14 | 7708 | no2nm | 3 | web | out of calibration range; but within working range |
20 | B | 1 | 20111203 | 221924 | 2011-12-03T22:19:24.00Z | 22.33351 | -35.86743 | GT-C | 14 | 7708 | po4nm | 5 | web | out of working range |
20 | B | 1 | 20111203 | 221924 | 2011-12-03T22:19:24.00Z | 22.33351 | -35.86743 | GT-C | 16 | 7706 | no2nm | 3 | web | out of calibration range; but within working range |
20 | B | 1 | 20111203 | 221924 | 2011-12-03T22:19:24.00Z | 22.33351 | -35.86743 | GT-C | 16 | 7706 | po4nm | 5 | web | out of working range |
20 | B | 1 | 20111203 | 221924 | 2011-12-03T22:19:24.00Z | 22.33351 | -35.86743 | GT-C | 18 | 7704 | no2nm | 3 | web | out of calibration range; but within working range |
20 | B | 1 | 20111203 | 221924 | 2011-12-03T22:19:24.00Z | 22.33351 | -35.86743 | GT-C | 18 | 7704 | no3nm | 3 | web | out of calibration range; but within working range |
20 | B | 1 | 20111203 | 221924 | 2011-12-03T22:19:24.00Z | 22.33351 | -35.86743 | GT-C | 18 | 7704 | po4nm | 5 | web | out of working range |
20 | B | 1 | 20111203 | 221924 | 2011-12-03T22:19:24.00Z | 22.33351 | -35.86743 | GT-C | 20 | 7702 | po4nm | 5 | web | out of working range |
20 | B | 2 | 20111203 | 234549 | 2011-12-03T23:45:49.20Z | 22.33304 | -35.86704 | SIOR | 1 | 7722 | reft | 3 | mcj | Deep SBE35T -0.008 vs CTDT; unstable SBE35T reading. Code questionable. |
20 | B | 2 | 20111203 | 234549 | 2011-12-03T23:45:49.20Z | 22.33304 | -35.86704 | SIOR | 3 | 7724 | bot | 2 | clog | 735m bottle accidentally tripped 5m too deep; on-the-fly while winch slowing near target. |
20 | B | 2 | 20111203 | 234549 | 2011-12-03T23:45:49.20Z | 22.33304 | -35.86704 | SIOR | 3 | 7724 | reft | 3 | mcj | SBE35T; CTDT1; CTDT2 all disagree; very unstable SBE35T reading on-the-fly. Code questionable. |
20 | B | 2 | 20111203 | 234549 | 2011-12-03T23:45:49.20Z | 22.33304 | -35.86704 | SIOR | 9 | 7730 | reft | 3 | mcj | very unstable SBE35T reading in gradient. Code questionable. |
20 | B | 2 | 20111203 | 234549 | 2011-12-03T23:45:49.20Z | 22.33304 | -35.86704 | SIOR | 10 | 7731 | reft | 3 | mcj | SBE35T; CTDT1; CTDT2 all disagree; unstable SBE35T reading in gradient. Code questionable. |
20 | B | 6 | 20111204 | 153936 | 2011-12-04T15:39:36.00Z | 22.33302 | -35.86707 | SIOR | 2 | 7779 | bot | 2 | clog | second bottle fired at 735m unintentionally; while still stopped for sample 601. |
20 | B | 6 | 20111204 | 153936 | 2011-12-04T15:39:36.00Z | 22.33302 | -35.86707 | SIOR | 13 | 7790 | salt | 2 | rlp | Salt 13; is surface pumped sample associated with cast. |
20 | B | 8 | 20111205 | 042438 | 2011-12-05T04:24:37.80Z | 22.37557 | -35.86777 | SIOR | 5 | 7804 | reft | 3 | mcj | very unstable SBE35T reading in gradient. Code questionable. |
20 | B | 8 | 20111205 | 042438 | 2011-12-05T04:24:37.80Z | 22.37557 | -35.86777 | SIOR | 11 | 7810 | reft | 3 | mcj | SBE35T; CTDT1; CTDT2 all disagree; very unstable SBE35T reading in gradient. Code questionable. |
20 | B | 9 | 20111205 | 085931 | 2011-12-05T08:59:31.20Z | 22.37556 | -35.86778 | SIOR | 8 | 7819 | salt | 3 | mcj | Deep salinity is +0.008 vs CTDS; code questionable. |
20 | B | 10 | 20111205 | 123722 | 2011-12-05T12:37:22.20Z | 22.37635 | -35.868 | GT-C | 3 | 7845 | bot | 2 | clog | Changed spigot and sipper tube on GoFlo 33 before cast; valve was slightly leaky. |
20 | B | 10 | 20111205 | 123722 | 2011-12-05T12:37:22.20Z | 22.37635 | -35.868 | GT-C | 8 | 7840 | salt | 2 | cms | Bottle value matches 1007 and CTD. Code acceptable. ANALYST: Salt 8; thimble popped loose before wiping; very wet; possible contamination. |
20 | B | 10 | 20111205 | 123722 | 2011-12-05T12:37:22.20Z | 22.37635 | -35.868 | GT-C | 9 | 7839 | salt | 2 | cms | Bottle value matches 1010 and CTD. Code acceptable. ANALYST: Salt 9; thimble came out with cap; probable contamination. |
20 | B | 10 | 20111205 | 123722 | 2011-12-05T12:37:22.20Z | 22.37635 | -35.868 | GT-C | 12 | 7836 | salt | 2 | cms | Bottle value matches 1011 and CTD. Code acceptable. ANALYST: Salt 12; thimble came out with cap; readings erratic. |
20 | B | 10 | 20111205 | 123722 | 2011-12-05T12:37:22.20Z | 22.37635 | -35.868 | GT-C | 14 | 7834 | salt | 2 | cms | Bottle value matches 1013 and CTD. Code acceptable. ANALYST: Salt 14; thimble came out with cap; readings erratic. |
20 | B | 11 | 20111205 | 164639 | 2011-12-05T16:46:39.00Z | 22.37636 | -35.868 | SIOR | 9 | 7856 | reft | 3 | mcj | SBE35T; CTDT1; CTDT2 all disagree; in gradient. Code questionable. |
20 | B | 11 | 20111205 | 164639 | 2011-12-05T16:46:39.00Z | 22.37636 | -35.868 | SIOR | 11 | 7858 | reft | 3 | mcj | SBE35T +0.028 vs CTDT; unstable SBE35T reading in gradient. Code questionable. |
21 | B | 1 | 20111206 | 140207 | 2011-12-06T14:02:07.20Z | 20.88388 | -32.62473 | GT-C | 4 | 7882 | salt | 3 | cms | Bottle salt value does not match 103 nor CTD by 2 orders of magnitude; in high gradient region. Code questionable. |
21 | B | 1 | 20111206 | 140207 | 2011-12-06T14:02:07.20Z | 20.88388 | -32.62473 | GT-C | 13 | 7873 | no2nm | 5 | web | out of working range |
21 | B | 1 | 20111206 | 140207 | 2011-12-06T14:02:07.20Z | 20.88388 | -32.62473 | GT-C | 13 | 7873 | po4nm | 5 | web | out of working range |
21 | B | 1 | 20111206 | 140207 | 2011-12-06T14:02:07.20Z | 20.88388 | -32.62473 | GT-C | 15 | 7871 | no2nm | 5 | web | out of working range |
21 | B | 1 | 20111206 | 140207 | 2011-12-06T14:02:07.20Z | 20.88388 | -32.62473 | GT-C | 15 | 7871 | po4nm | 5 | web | out of working range |
21 | B | 1 | 20111206 | 140207 | 2011-12-06T14:02:07.20Z | 20.88388 | -32.62473 | GT-C | 17 | 7869 | no2nm | 5 | web | out of working range |
21 | B | 1 | 20111206 | 140207 | 2011-12-06T14:02:07.20Z | 20.88388 | -32.62473 | GT-C | 17 | 7869 | po4nm | 5 | web | out of working range |
21 | B | 1 | 20111206 | 140207 | 2011-12-06T14:02:07.20Z | 20.88388 | -32.62473 | GT-C | 17 | 7869 | salt | 3 | cms | Bottle salt value matches closely with CTD and 218. Code acceptable. ANALYST: Salt 17; thimble popped loose before wiping; very wet. Possible contamination. |
21 | B | 1 | 20111206 | 140207 | 2011-12-06T14:02:07.20Z | 20.88388 | -32.62473 | GT-C | 19 | 7867 | no2nm | 3 | web | out of calibration range; but within working range |
21 | B | 1 | 20111206 | 140207 | 2011-12-06T14:02:07.20Z | 20.88388 | -32.62473 | GT-C | 19 | 7867 | no3nm | 3 | web | out of calibration range; but within working range |
21 | B | 1 | 20111206 | 140207 | 2011-12-06T14:02:07.20Z | 20.88388 | -32.62473 | GT-C | 19 | 7867 | po4nm | 5 | web | out of working range |
21 | B | 2 | 20111206 | 152145 | 2011-12-06T15:21:45.00Z | 20.88386 | -32.62473 | SIOR | 4 | 7889 | bot | 2 | slog | Bottle 4; 5 or 6 bottom cap was popped open by tag line during recovery; difficult to see which bottle was snapped. |
21 | B | 2 | 20111206 | 152145 | 2011-12-06T15:21:45.00Z | 20.88386 | -32.62473 | SIOR | 5 | 7890 | bot | 2 | slog | Bottle 4; 5 or 6 bottom cap was popped open by tag line during recovery; difficult to see which bottle was snapped. |
21 | B | 2 | 20111206 | 152145 | 2011-12-06T15:21:45.00Z | 20.88386 | -32.62473 | SIOR | 5 | 7890 | reft | 3 | mcj | SBE35T; CTDT1; CTDT2 all disagree; very unstable SBE35T reading. Code questionable. |
21 | B | 2 | 20111206 | 152145 | 2011-12-06T15:21:45.00Z | 20.88386 | -32.62473 | SIOR | 6 | 7891 | bot | 2 | slog | Bottle 4; 5 or 6 bottom cap was popped open by tag line during recovery; difficult to see which bottle was snapped. |
21 | B | 2 | 20111206 | 152145 | 2011-12-06T15:21:45.00Z | 20.88386 | -32.62473 | SIOR | 11 | 7896 | reft | 3 | mcj | SBE35T +0.018 vs CTDT; unstable SBE35T reading in gradient. Code questionable. |
22 | B | 1 | 20111207 | 103030 | 2011-12-07T10:30:30.00Z | 19.43336 | -29.38322 | GT-C | 7 | 7919 | salt | 2 | cms | Bottle salt value agrees to CTD and 108. Code acceptable. ANALYST: Salt 7; thimble came out with cap; very wet. Probably contamination. |
22 | B | 1 | 20111207 | 103030 | 2011-12-07T10:30:30.00Z | 19.43336 | -29.38322 | GT-C | 14 | 7912 | no2nm | 5 | web | out of working range |
22 | B | 1 | 20111207 | 103030 | 2011-12-07T10:30:30.00Z | 19.43336 | -29.38322 | GT-C | 14 | 7912 | po4nm | 5 | web | out of working range |
22 | B | 1 | 20111207 | 103030 | 2011-12-07T10:30:30.00Z | 19.43336 | -29.38322 | GT-C | 16 | 7910 | no2nm | 5 | web | out of working range |
22 | B | 1 | 20111207 | 103030 | 2011-12-07T10:30:30.00Z | 19.43336 | -29.38322 | GT-C | 16 | 7910 | po4nm | 5 | web | out of working range |
22 | B | 1 | 20111207 | 103030 | 2011-12-07T10:30:30.00Z | 19.43336 | -29.38322 | GT-C | 17 | 7909 | salt | 3 | cms | Bottle salt value high by about 30 units in high gradient region. Code questionable. |
22 | B | 1 | 20111207 | 103030 | 2011-12-07T10:30:30.00Z | 19.43336 | -29.38322 | GT-C | 18 | 7908 | no2nm | 3 | web | out of calibration range; but within working range |
22 | B | 1 | 20111207 | 103030 | 2011-12-07T10:30:30.00Z | 19.43336 | -29.38322 | GT-C | 18 | 7908 | po4nm | 5 | web | out of working range |
22 | B | 1 | 20111207 | 103030 | 2011-12-07T10:30:30.00Z | 19.43336 | -29.38322 | GT-C | 18 | 7908 | salt | 3 | cms | Bottle salt value high by about 30 units in high gradient region. Code questionable. |
22 | B | 1 | 20111207 | 103030 | 2011-12-07T10:30:30.00Z | 19.43336 | -29.38322 | GT-C | 20 | 7906 | no2nm | 3 | web | out of calibration range; but within working range |
22 | B | 1 | 20111207 | 103030 | 2011-12-07T10:30:30.00Z | 19.43336 | -29.38322 | GT-C | 20 | 7906 | no3nm | 3 | web | out of calibration range; but within working range |
22 | B | 1 | 20111207 | 103030 | 2011-12-07T10:30:30.00Z | 19.43336 | -29.38322 | GT-C | 20 | 7906 | po4nm | 3 | web | out of calibration range; but within working range |
22 | B | 2 | 20111207 | 115428 | 2011-12-07T11:54:28.20Z | 19.43298 | -29.383 | SIOR | 3 | 7928 | salt | 3 | cms | Bottle salt value high by 50 units in high gradient region. Code questionable. |
22 | B | 2 | 20111207 | 115428 | 2011-12-07T11:54:28.20Z | 19.43298 | -29.383 | SIOR | 8 | 7933 | salt | 3 | cms | Bottle salt value low by 30 units in high gradient region. Code questionable. |
22 | B | 5 | 20111207 | 233214 | 2011-12-07T23:32:13.80Z | 19.433 | -29.38301 | GT-C | 3 | 7980 | salt | 2 | cms | Bottle salt value agrees to CTD and 504. Code acceptable. ANALYST: Salt 3; thimble came out with cap; probable contamination. |
22 | B | 6 | 20111208 | 022842 | 2011-12-08T02:28:42.00Z | 19.43301 | -29.38303 | SIOR | 13 | 7995 | salt | 2 | rlp | Salt 13 is surface pumped sample associated with cast. |
23 | B | 1 | 20111209 | 041057 | 2011-12-09T04:10:57.00Z | 18.3897 | -26.76529 | GT-C | 13 | 8017 | bot | 2 | clog | This trip may have been taken while winch moving too fast. |
23 | B | 1 | 20111209 | 041057 | 2011-12-09T04:10:57.00Z | 18.3897 | -26.76529 | GT-C | 13 | 8017 | no2nm | 5 | web | out of working range |
23 | B | 1 | 20111209 | 041057 | 2011-12-09T04:10:57.00Z | 18.3897 | -26.76529 | GT-C | 13 | 8017 | po4nm | 5 | web | out of working range |
23 | B | 1 | 20111209 | 041057 | 2011-12-09T04:10:57.00Z | 18.3897 | -26.76529 | GT-C | 14 | 8016 | bot | 2 | clog | This trip may have been taken while winch moving too fast. |
23 | B | 1 | 20111209 | 041057 | 2011-12-09T04:10:57.00Z | 18.3897 | -26.76529 | GT-C | 15 | 8015 | no2nm | 5 | web | out of working range |
23 | B | 1 | 20111209 | 041057 | 2011-12-09T04:10:57.00Z | 18.3897 | -26.76529 | GT-C | 15 | 8015 | po4nm | 5 | web | out of working range |
23 | B | 1 | 20111209 | 041057 | 2011-12-09T04:10:57.00Z | 18.3897 | -26.76529 | GT-C | 17 | 8013 | no2nm | 5 | web | out of working range |
23 | B | 1 | 20111209 | 041057 | 2011-12-09T04:10:57.00Z | 18.3897 | -26.76529 | GT-C | 17 | 8013 | po4nm | 5 | web | out of working range |
23 | B | 1 | 20111209 | 041057 | 2011-12-09T04:10:57.00Z | 18.3897 | -26.76529 | GT-C | 19 | 8011 | no2nm | 3 | web | out of calibration range; but within working range |
23 | B | 1 | 20111209 | 041057 | 2011-12-09T04:10:57.00Z | 18.3897 | -26.76529 | GT-C | 19 | 8011 | po4nm | 5 | web | out of working range |
23 | B | 2 | 20111209 | 053007 | 2011-12-09T05:30:07.20Z | 18.38845 | -26.76393 | SIOR | 11 | 8040 | reft | 3 | mcj | SBE35T; CTDT1; CTDT2 all disagree; unstable SBE35RT reading in gradient. Code questionable. |
23 | B | 2 | 20111209 | 053007 | 2011-12-09T05:30:07.20Z | 18.38845 | -26.76393 | SIOR | 13 | 8042 | salt | 2 | rlp | ANALYST: Salt 13 is surface pumped sample associated with cast. |
24 | B | 1 | 20111209 | 190357 | 2011-12-09T19:03:57.00Z | 17.39999 | -24.50004 | GT-C | 6 | 8066 | bot | 2 | clog | Before cast; sipper tube re-inserted into valve (GF6). |
24 | B | 1 | 20111209 | 190357 | 2011-12-09T19:03:57.00Z | 17.39999 | -24.50004 | GT-C | 7 | 8065 | salt | 2 | cms | Bottle salt value agrees with CTD and 108. code acceptable. ANALYST: Salt 7; thimble came out with cap readings erratic. |
24 | B | 1 | 20111209 | 190357 | 2011-12-09T19:03:57.00Z | 17.39999 | -24.50004 | GT-C | 13 | 8059 | salt | 3 | cms | Bottle salt value matches 114; however value 2.5 orders of magnitude low for high gradient region. Code questionable. |
24 | B | 1 | 20111209 | 190357 | 2011-12-09T19:03:57.00Z | 17.39999 | -24.50004 | GT-C | 14 | 8058 | no2nm | 5 | web | out of working range |
24 | B | 1 | 20111209 | 190357 | 2011-12-09T19:03:57.00Z | 17.39999 | -24.50004 | GT-C | 14 | 8058 | po4nm | 5 | web | out of working range |
24 | B | 1 | 20111209 | 190357 | 2011-12-09T19:03:57.00Z | 17.39999 | -24.50004 | GT-C | 14 | 8058 | salt | 3 | cms | Bottle salt value matches 113; however value 2.5 orders of magnitude low for high gradient region. Code questionable. |
24 | B | 1 | 20111209 | 190357 | 2011-12-09T19:03:57.00Z | 17.39999 | -24.50004 | GT-C | 16 | 8056 | no2nm | 5 | web | out of working range |
24 | B | 1 | 20111209 | 190357 | 2011-12-09T19:03:57.00Z | 17.39999 | -24.50004 | GT-C | 16 | 8056 | po4nm | 5 | web | out of working range |
24 | B | 1 | 20111209 | 190357 | 2011-12-09T19:03:57.00Z | 17.39999 | -24.50004 | GT-C | 18 | 8054 | no2nm | 3 | web | out of calibration range; but within working range |
24 | B | 1 | 20111209 | 190357 | 2011-12-09T19:03:57.00Z | 17.39999 | -24.50004 | GT-C | 18 | 8054 | no3nm | 3 | web | out of calibration range; but within working range |
24 | B | 1 | 20111209 | 190357 | 2011-12-09T19:03:57.00Z | 17.39999 | -24.50004 | GT-C | 18 | 8054 | po4nm | 5 | web | out of working range |
24 | B | 1 | 20111209 | 190357 | 2011-12-09T19:03:57.00Z | 17.39999 | -24.50004 | GT-C | 20 | 8052 | no2nm | 3 | web | out of calibration range; but within working range |
24 | B | 1 | 20111209 | 190357 | 2011-12-09T19:03:57.00Z | 17.39999 | -24.50004 | GT-C | 20 | 8052 | no3nm | 3 | web | out of calibration range; but within working range |
24 | B | 1 | 20111209 | 190357 | 2011-12-09T19:03:57.00Z | 17.39999 | -24.50004 | GT-C | 20 | 8052 | po4nm | 5 | web | out of working range |
24 | B | 1 | 20111209 | 190357 | 2011-12-09T19:03:57.00Z | 17.39999 | -24.50004 | GT-C | 24 | 8048 | po4nm | 3 | web | out of calibration range; but within working range |
24 | B | 2 | 20111209 | 202407 | 2011-12-09T20:24:07.20Z | 17.40001 | -24.50005 | SIOR | 6 | 8077 | salt | 3 | cms | Bottle salt value -0.040 with CTD in high gradient region. Code questionable. |
24 | B | 2 | 20111209 | 202407 | 2011-12-09T20:24:07.20Z | 17.40001 | -24.50005 | SIOR | 8 | 8079 | reft | 3 | mcj | SBE35T; CTDT1; CTDT2 all disagree; in gradient. Code questionable. |
24 | B | 2 | 20111209 | 202407 | 2011-12-09T20:24:07.20Z | 17.40001 | -24.50005 | SIOR | 9 | 8080 | reft | 3 | mcj | SBE35T; CTDT1; CTDT2 all disagree; very unstable SBE35T reading in gradient. Code questionable. |